← 510-Whitesville-RVE-111125.pdf

Rebuilt HTML — PaddleOCR-VL (Baidu)

Content placed at each item's bbox to mirror the original PDF layout (font sizes are estimated). overlay · view JSON

REMINGTON & VERNICK ENGINEERS
5/P854-1
9 Allen Street Toms River, NJ 08753 O: (732) 286-9220 F: (732) 505-8416
November 11, 2025
Ms. Laura Morrison, Secretary Jackson Township Planning Board 95 West Veterans Highway Jackson Township, New Jersey 08527
Re: Application No. 854-1 / Escrow #P32338 Preliminary & Final Major Site Plan - Review #1 Applicant/Owner: 510 Whitesville, LLC Project Name: Atlantic Site Construction Office/Warehouse 510 Whitesville Road Block 22401, Lots 7, 8, 9, 10, 11 & 12 Our File: 1512-P-620
Dear Ms. Morrison & Planning Board Members:
REMINGTON & VERNICK ENGINEERS has received the above captioned Application for review. The Applicant is seeking preliminary and final site plan approval for the construction of a 3-story 15,000 sf office building; a 1-story 12,750 sf warehouse building with 4 units, a 1,575 sf storage shed, a 810 sf pipe storage shed, and an outdoor area for storing small machines the PM-1 – Pinelands Manufacturing Zone.
The subject property is located on the westerly side of Whitesville Road (C.R. 527). The site is located in the PM-1 – Pinelands Manufacturing Zone as well as the Conservation Overlay Zone and consists of 6.10 acres. The site is currently developed with a 1 story frame dwelling, a detached garage, a horse stable, 2 sheds, a gravel driveway, a gravel parking area, fencing, and a dirt path. The site is partially wooded and contains a wetlands buffer as approved by the Pinelands Commission File #2020-0045.001. The existing fence appears to encroach onto adjacent Lot 13.
The site improvements proposed at the front of the site include the following:
A 3-story 15,000 sf Office Building.
A 1,575 sf Storage Shed.
A 30 ft wide heavy duty pavement access drive.
76–9 ft x 18 ft parking spaces (partially curbed & 21 porous pavement & 3 standard asphalt pavement) includes 4 accessible parking spaces and 4 EV ready spaces.
24 ft wide access aisles (standard asphalt with a small portion of porous pavement.
A 12 ft x 45 ft loading zone (standard asphalt pavement).
Concrete sidewalk with accessible ramps.
A grass paver emergency access connecting the front and rear portions of the site.
An approximately 10 ft x 20 ft refuse enclosure.
An area to be restored to wooded condition.
The site improvements proposed at the rear of the site include the following:
A 1-story 12,750 sf Warehouse Building with 4 units.
www.rve.com
Jackson Township Planning Board Our file No. 1512-P-620
Page 2
An 810 sf Pipe Storage Shed.
An area for outdoor storage of small machinery. The ground surface is not indicated for this area.
Gravel parking and circulation areas.
Areas of porous pavement.
14-9 ft x 18 ft parking spaces (partially curbed, 6 gravel, 8 porous pavement).
23 - 10 ft x 40 ft truck parking spaces (gravel with porous pavement across the middle portion).
3 - 12 ft x 70 ft parking spaces (gravel with a small portion of porous pavement).
An area to be restored to wooded condition.
The overall site improvements include landscaping, lighting, and stormwater management. The site is to be serviced by public water and an on-site septic system. Access to the site is by way of a full access drive along Whitesville Road. The Applicant is proposing roadway improvements along Whitesville Road.
This report consists of our review of the Subject Application for conformance with the Jackson Township Land Use and Development Regulations Ordinance (Chapter 244) and is limited to planning issues. Engineering and legal issues shall be reviewed by the Board Engineer and Solicitor, respectively.
Comments are limited to the information presented to date. The Applicant may present additional information and testimony at the Board hearing.
I. OWNER & APPLICANT INFORMATION
Applicant/Owner
510 Whitesville, LLC 688 Cross Street, Suite A Lakewood, NJ 08701 732-363-5252
II. SUBMITTALS
TITLE / DESCRIPTIONPREPARED / SIGNED / SEALED BYDATEDATE LAST REVISED
Letter of TransmittalLaura Morrison Planning Board Secretary7/31/2025
Certificate of Zoning/Development PermitJeffrey Purpuro Zoning Officer7/30/2025
Land Development ApplicationApplicant/OwnerUndated
Statement of Operations6/30/2025
Land Development ChecklistUndated
Certification By Owner and/or Applicant1/8/2025
Fee Schedule & Escrow Account7/30/2025
Escrow Agreement1/8/2025
Corporate Disclosure Form1/8/2025
Land Use Disclosure StatementUndated
Jackson Township Planning Board Our file No. 1512-P-620
Page 3
TITLE / DESCRIPTIONPREPARED / SIGNED / SEALED BYDATEDATE LAST REVISED
Right of Entry Consent FormApplicant/Owner1/8/2025
Consent of Owner Form1/8/2025
Deed of Ownership4/3/2023
Land Use Disclosure StatementDonna Jennings, Esq. WilentzUndated
Letter of Submission6/30/2025
Letter of SubmissionEliezer Cohen, Project Coordinator YP Engineering P.C./Civil Core Consulting7/23/2025
Tree Removal Permit & Fee7/30/2025
Submission Letter for Jackson Township Environmental Commission approval6/16/2025
Submission Letter for Ocean County Soil Conservation District approval1/23/2025
Submission Letter for Jackson Township Bureau of Fire Protection approval5/24/2025
Submission Letter for Ocean County Planning Board approval1/22/2025
Submission Letter for Ocean County Health Department approval5/7/2024
Submission Letter for Jackson Township Police Department Traffic Safety Bureau approval6/16/2025
Preliminary & Final Major Site Plan for Block 22401, Lots 7-12, Jackson Township, Ocean County, New Jersey consisting of 23 sheetsYosef Portnoy, P.E. YP Engineering P.C./Civil Core Consulting1/22/20256/5/2025
Vehicle Circulation Plans consisting of 3 sheets1/22/20256/9/2025
Land Use Disclosure StatementUndated
Boundary & Topographic Survey consisting of 1 sheetChristopher Bouffard, P.L.S. Newlines Land Consultants3/4/20212/5/2025
Land Use Disclosure StatementNaftoli Gut, R.A. GutVann ArchitectureUndated
Architectural Floor Plans & Elevations for the Office Building consisting of 8 sheets3/24/2025
Architectural Floor Plans & Elevations for the Contractor Shop/Warehouse consisting of 3 sheets3/24/2025
Jackson Township Planning Board Our file No. 1512-P-620
Page 4
TITLE / DESCRIPTIONPREPARED / SIGNED / SEALED BYDATEDATE LAST REVISED
Traffic Impact AnalysisScott T. Kennel McDonough & Rea Assoc. Inc.1/14/2025
Water Service AvailabilityEarl Quijano Jackson Township MUA5/9/2024
Statement of Utilities5/10/2024
Letter of ConcernsP.O. R. Reiff #278 Jackson Township Traffic Safety Unit8/7/2024
Letter of Approval with ExceptionsScott Rauch Fire Official7/24/2025
Review LetterCharles Horner, P.P. Pinelands Commission5/24/2024
Review Letter7/1/2024
Inconsistent Certificate of Filing12/24/2024
III. ZONING
A. Use:
The subject property is located within the PM-Pinelands Manufacturing Zone District as well as the Conservation Overlay Zone. The Applicant is seeking preliminary and final site plan approval for the construction of a 3-story 15,000 sf office building; a 1-story 12,750 sf warehouse building with 4 units, a 1,575 sf storage shed, a 810 sf pipe storage shed, and an outdoor area for storing small machines.
1. Office Use:
Per §244-97A(1) general office facilities is a permitted use.
Per §244-97A(2) professional and commercial office facilities is a permitted use.
2. Warehouse Use:
Per §244-97A(5) the warehousing or storage of goods and products, provided that no goods are sold from the premises, and provided further that all items to be stored are within an enclosed building.
The Applicant shall provide testimony to discuss the warehouse use in detail. The testimony shall include the proposed area for the storage of small machines.
3. Storage Sheds:
Per §244-57B(6) accessory uses customarily associated with the industrial, research or office uses permitted in § 244-97A above.
The Applicant shall provide testimony to discuss the proposed storage sheds in detail to determine if they are a permitted accessory use.
Jackson Township Planning Board Our file No. 1512-P-620
Page 5
B. Area & Bulk Standards:
PM-1 Pinelands Manufacturing Zone - §244-97D
ITEMREQUIREDPROPOSEDSTATUS
Minimum Lot Area2 acres6.1 acresConforms
Lot Area (Wetlands Excluded)TBD(1)
Minimum Lot Frontage200 ft214.78 ftConforms
Minimum Front Yard Setback Major Road100 ft113.34 ftConforms
Minimum Front Yard Setback Other Roads60 ft113.34 ftConforms
Minimum Rear Yard Setback50 ft211.65 ftConforms
Minimum Side Yard Setback25 ft30 ftConforms
Minimum Side Yard Setback (Combined)60 ft>60 ftConforms
Maximum Building Height50 ft45 ftConforms
Maximum Lot Coverage50%49.71% (2)Conforms
Parking Area Setbacks
From ROW20 ft41.68 ftConforms
From Residential20 ftN/AN/A
From Nonresidential10 ft10 ftConforms
Min. Required Parking Spaces
Office Use (15,000 sf) 1 parking space/200 sf of gsf15,000 sf/200 sf = 75 spaces90 spaces + 4 EV credited spaces
Warehouse Use (12,750 sf) 1 parking space/1,500 sf + 1 per vehicle used in connection with the business.12,750 sf/1,500 sf = 9 spaces + number of vehicles used in connection with the business
Total Parking Spaces84 spaces94 spacesConforms
Accessible Parking Spaces4 spaces4 spacesComplies
V – Variance TBD – To Be Determined N/A – Not Applicable
(1) Per §244-45C(1)(c) all wetlands, as identified and verified, pursuant to the LOI (letter of interpretation) shall be excluded from the gross acreage for purposes of calculating maximum lot coverage (building and impervious) for nonresidential developments. No wetlands are
Jackson Township Planning Board Our file No. 1512-P-620 Page 6
delineated on the site. Testimony shall be provided to confirm that there are no wetlands on-site.
(2) Per §244-45C(1)(c) all wetlands, as identified and verified, pursuant to the LOI (letter of interpretation) shall be excluded from the gross acreage for purposes of calculating maximum lot coverage (building and impervious) for nonresidential developments. No wetlands are delineated on the site. Testimony shall be provided to confirm that there are no wetlands on-site.
C. Other Provisions and Requirements in the PM-1 Zone - Per 244-97E
Each use located in the PM-1 Zone shall provide truck loading and unloading facilities on the same lot and in other than the required front yard so as to permit the transfer of goods in other than a public street. This requirement appears to have been met. Testimony shall be provided.
No required off-street loading areas shall be located in any required front setback. This requirement appears to have been met. Testimony shall be provided.
Where the PM-1 Zone abuts a residential zone, whether along a property line or across a street, there shall be provided a one-hundred-foot buffer screening strip, as set forth in § 244-193. This requirement does not apply.
Each use permitted in the PM-1 Zone shall be served by a public sewage disposal system or by a private disposal system which meets the approval of the State and Township Boards of Health and the Jackson Township Municipal Utilities Authority. Any private disposal system shall be so designed as will, in the opinion of the Township Engineer, enable the system to be efficiently connected to the prospective public disposal system when constructed. The Applicant shall provide testimony to discuss compliance with this requirement.
Uses established in this zone shall set aside a minimum of 20% of the area of the tract devoted to such use for seeding and landscaping and shall use this area for no other purpose. This requirement appears to have been met. Testimony shall be provided.
All industrial activities or processes shall take place within a completely enclosed building. Incidental storage out of doors shall be shielded from any street or adjacent residential zone by fencing, landscaping, or other appropriate measure. The Applicant shall provide testimony to discuss compliance with this requirement.
All new streets, whether intended for public dedication or to remain as private streets, shall provide curbing and shall be designed to provide a forty-foot paved surface within a sixty-six-foot right-of-way. Such streets shall be constructed in accordance with specifications prepared by the Township Engineer for industrial-type streets. No new street is proposed. This requirement is not applicable.
Industrial parks containing such permitted uses as set forth herein shall have a total area of not less than 20 acres. All streets within industrial parks shall be private, and there shall be adequate provisions for repair and maintenance so as to relieve the Township of Jackson from any responsibility for the upkeep of such streets. This requirement does not apply.
No use shall be conducted in such a way as to discharge any treated or untreated industrial waste, except as shall be approved by the Health Officer, Jackson Township. Municipal Utilities Authority and any applicable state agency having jurisdiction in such matters. The Applicant
Jackson Township Planning Board Our file No. 1512-P-620
Page 7
shall provide testimony to discuss compliance with this requirement.
10. Provision and use of water. All water requirements shall be stated in the application. Water shall be supplied from wells only after an approved or accepted geologic study of furnished by the applicant and certification by a professional geologist that the underground water supply and levels will not be appreciably altered in such a way as to endanger the water level and supply for other properties. The site is to be serviced by public water. No wells are proposed. Testimony shall be provided to confirm no wells are proposed.
D. Conservation Zone Overlay
Per §244-45C(1) all properties which fall within the Conservation Zone Overlay shall be regulated by the underlying zone or district within which they are found, except that the following additional requirements shall apply.
Per §244-45C(1)(a) all applications for major site plan or major subdivision approvals shall be required to submit a valid NJDEP letter of interpretation and/or permit which identifies all freshwater wetlands and wetlands buffers/transition areas on the property or properties included in the application before the application can be deemed complete. The Applicant has delineated a wetland's buffers on the plans as approved per Pinelands #2020-0045.001 as shown on a plan titled "Environmental Constraints Plan, prepared by Professional Design Services, LLC, dated January 19, 2023." A copy of the plan shall be provided to our office.
Per §244-45C(1)(b) all wetlands, wetlands buffers, transition areas, and riparian buffers must be properly identified and delineated on all submitted plans for major site plan or major subdivision approvals before the application can be deemed complete. The Applicant has delineated a wetland's buffers on the plans as approved per Pinelands #2020-0045.001 as shown on a plan titled "Environmental Constraints Plan, prepared by Professional Design Services, LLC, dated January 19, 2023." A copy of the plan shall be provided to our office.
Per §244-45C(1)(c) all wetlands, as identified and verified, pursuant to the LOI (letter of interpretation) shall be excluded from the gross acreage for purposes of calculating maximum lot coverage (building and impervious) for nonresidential developments. No wetlands are shown on the site. A copy of the Environmental Constraints plan shall be provided to our office to confirm.
Per §244-45C(1)(d) all required setbacks shall be taken from the wetlands limits pursuant to the LOI (letter of interpretation). This does not appear to be applicable to the proposed development.
IV. SITE PLAN ISSUES
With the exception of the following, site plan issues are deferred to the Board Engineer.
A. General
The statement of operations indicates that “The proposed development will be used to support Applicant’s construction business by housing Applicant’s office functions and providing warehouse space. The warehouse will be primarily to store and prepare materials in the Applicant’s construction business”. Testimony shall be provided to discuss the uses proposed.
Per §244-97A(5) the warehousing or storage of goods and products, provided that no goods are sold from the premises, and provided further that all items to be stored are within an enclosed building. Testimony shall be provided to ensure that the proposed warehouse use is a permitted
Jackson Township Planning Board Our file No. 1512-P-620
Page 8
use.
The Applicant shall provide testimony to indicate if any outdoor storage of materials or goods is proposed.
The Applicant shall provide testimony to discuss equipment and vehicle maintenance. Does the Applicant anticipate providing the maintenance on-site.
The Applicant shall provide testimony to discuss what types of small machinery is intended to be stored outside. The statement of operations indicates that “The site will also have storage of smaller construction equipment and vehicles used in the business operation.”
In the area of the small machinery, labels shall be provided to identify the ground surface as well as the material surrounding that area.
The Applicant shall provide testimony to discuss what is intended to be stored in the proposed storage shed closest to the office building to determine if the shed is a permitted accessory use.
The Applicant shall provide testimony to discuss what is intended to be stored in the proposed pipe storage shed closest to the warehouse building to determine if the shed is a permitted accessory use.
The Applicant shall provide testimony to discuss the number of suites anticipated for each floor and verify the entire building is for only 1 tenant.
The Applicant shall provide testimony to discuss the reason 4 units are proposed for the warehouse building, whereas the statement of operations appears to indicate the entire warehouse is for only 1 tenant.
The warehouse building consists of 8 garage doors on the north side of the building and 8 garage doors on the south side of the building. There are 23 – 10 ft x 40 ft truck spaces that appear to block access to the warehouse building. The truck parking spaces do not necessarily align with the garage doors. Testimony shall be provided to discuss the proposed circulation within the building.
The Applicant shall provide testimony to discuss the need for the 23 – 10 ft x 40 ft truck spaces and the 3 – 12 ft x 70 ft truck spaces.
Testimony shall be provided describing the ownership of the site improvements as well as the warehouse building and the office building. Testimony shall be provided describing the maintenance responsibilities for the site improvements.
The Applicant shall provide testimony to discuss the proposed operations in sufficient detail to indicate the effects of the use in producing traffic congestion, noise, glare, air pollution, fire hazards or safety hazard, the hours of operation of the use, the number of shifts to be worked, the number of employees in each shift, the number of vehicles to be stored or parked on the site and provisions to be made for site maintenance.
The Applicant shall provide testimony to indicate if the project is anticipated to be constructed in Phases.
B. Architectural Considerations
The office building indicates an open office area for all 3 floors. The Applicant shall provide testimony to discuss the number of tenants anticipated.
The Applicant shall provide testimony to discuss if there are any uses anticipated on the roof. If so, the architectural plans should be revised accordingly.
The warehouse building indicates 4 units. Testimony shall be provided to discuss the number of
Jackson Township Planning Board Our file No. 1512-P-620
Page 9
tenants proposed.
The warehouse building only provides bathroom facilities with access from Unit #2. Testimony shall be provided to discuss access to the bathroom facilities for Units #1, #3 & #4.
The site plans and architectural plans shall be revised to be consistent with the square footage of the office building and the warehouse building.
The Applicant shall provide testimony to discuss the exterior finishes of the building.
Our office recommends that solar be incorporated into the building/site design.
C. Signs
The Applicant shall provide testimony to indicate if any site monument or freestanding identification signage is proposed. If so, the location shall be shown on the plans and details provided to determine compliance with §244-207.
The Applicant shall provide testimony to indicate if any wall mounted identification signage is proposed for the warehouse building. If so, the location shall be shown on the plans and details provided to determine compliance with §244-207.
There appears to be wall signage proposed for the office building as indicated on the architectural elevations. Details shall be provided to determine compliance with §244-207.
D. Traffic, Circulation, Parking and Loading
Per §244-197N(1) the minimum parking spaces required for the proposed warehouse use as calculated above are 9 parking spaces plus the number of vehicles used in connection with the business. The Applicant shall provide testimony to discuss the number of vehicles used in connection with the business.
The most easterly row of parking spaces is labeled as 14 parking spaces, whereas 15 parking spaces of provided. Revise accordingly.
Details shall be provided for the EV ready spaces.
Per §244-203A sidewalks and curbing shall be required along all street frontages as a condition relating to any development for which approval is granted by the Planning Board or Board of Adjustment. There is no sidewalk and partial curb proposed along the frontage of Whitesville Road. Sidewalk and additional curb shall be provided, or the Applicant shall request a waiver and contribute to the Jackson Township Pedestrian Safety Fund.
Per §244-197G the perimeter of all parking areas and internal islands within all parking areas open to the general public shall have continuous cast-in-place concrete curbing, whereas partial curbing is proposed. The plan shall be revised, or the Applicant shall request a waiver.
The linework on the site plan is difficult to determine where curb is proposed. The plan shall be revised to clarify where curb is proposed.
There is a wheel stop detail provided. The locations of the wheel stops shall be shown and labeled on the plans.
Per §244-197H all parking areas shall provide pavement, whereas the parking areas and circulation aisles for the passenger vehicles and trucks at the rear of the site is gravel with portions of porous pavement. The plan shall be revised, or the Applicant shall request a waiver. Testimony shall be provided to discuss the adequacy of gravel for tractor trailer circulation.
The Applicant shall provide testimony to discuss the longevity of the porous pavement in the area
Jackson Township Planning Board Our file No. 1512-P-620 Page 10
of the tractor trailers.
There is 56 ft proposed between the tractor trailer parking and the passenger vehicle parking. The Applicant should demonstrate the tractor trailer circulation in this area to ensure adequate space is provided for circulation.
Per §244-197J(2)(a)[2][c] no parking stalls shall utilize the required entrance and exit drives or major circulation drives as parking access aisles, whereas the parking accesses the main circulation drive. Our office is concerned that the 38 parking spaces along the north property line access the main drive aisle that permits tractor trailers. The Applicant has requested a waiver. Testimony shall be provided to discuss tractor trailer circulation and pedestrian safety.
All depressed curbs should be shaded and dimensioned for clarity.
The accessible ramps shall be labeled.
No sidewalks are proposed for the warehouse portion of the site. Testimony shall be provided to discuss pedestrian and accessible circulation. Accessible circulation shall be in compliance with ADA regulations.
The Applicant shall provide testimony to discuss the size trucks and equipment that are proposed to enter and exit the site.
The width of the grass paver emergency access shall be dimensioned on the site plan.
Our office defers all fire prevention and fire safety issues to the Township Fire Official.
The Applicant shall provide testimony to discuss the proposed improvements along Whitesville Road. Approval of Ocean County Planning Board is required.
Testimony should be provided to discuss any traffic impacts as a result of the proposed development.
E. Utilities
The Applicant is proposing to service the site with public water by connecting into an existing water main within Whitesville Road. The Applicant shall obtain an approval from the Jackson Township MUA.
The Applicant is proposing to service the site with an on-site septic system. Approvals from the Ocean County Board of Health, and the Pinelands Commission may be required.
F. Landscaping
The Applicant is proposing to restore 2 areas back to a wooded condition. Note #3 on sheet 12 of 23 indicates that the Applicant proposes to plant 225 trees as part of the landscape and wetlands buffer restoration plans. Sheet 9 of 23 Buffer Restoration Plan shall label the restoration areas such as A & B and provide a plant list and spacing between the trees.
All tree removal shall be in accordance with Chapter 405 of the Township of Jackson Ordinance.
A Landscape & Tree Save Plan shall be prepared in accordance with §405-5 addressing Tree Removal and Tree Preservation.
Our office defers compliance for the proposed tree removal and replacement to the Jackson Township Tree Specialist.
Jackson Township Planning Board Our file No. 1512-P-620
Page 11
A note shall be added to the landscape plan indicating that “All tree stumps and other tree parts or other debris shall be removed from the site and disposed of in accordance with the law. No tree stumps, portions of a tree trunk or limbs shall be buried anywhere in the development.”
A note shall be added to the landscape plan indicating that “The developer shall selectively thin or remove all dead or dying vegetation, either standing or fallen, and shall remove, including grubbing out stumps, all undesirable trees and other growth.”
A note shall be added to the landscape plan indicating that “No topsoil shall be removed from the site or used as spoil. All regraded areas and all lawn areas shall be covered by four inch minimum thickness of topsoil.”
The tree planting detail shall be revised to include wrapping. Each tree shall be wrapped with expandable paper or cloth treated to last at least one year. The wrap shall extend from the ground level up the trunk to the first branches. The wrap shall be fastened at each end with a material that will permit tree growth.
Landscape specification #17A should be revised to reference a 2 yr guarantee period.
Per §244-201 exterior mechanical equipment is required to be screened from public view. All exterior mechanical equipment shall be shown on the plans and screened accordingly.
The Applicant should provide testimony regarding the irrigation of the proposed landscaping.
G. Lighting
Per §244-197J(1)(f) lighting is required for all parking lots and shall provide a minimum lighting level of 0.5 footcandles throughout the parking area and access drives, whereas there are areas in the parking lot for the office building that are less than 0.5 footcandles. The plan should be revised, or the Applicant shall request a waiver. Testimony shall be provided to discuss the adequacy of the lighting provided for the parking lot for the office building.
Per §244-197J(1)(f) lighting is required for all parking lots and shall provide a minimum lighting level of 0.5 footcandles throughout the parking area and access drives, whereas no lighting is proposed for the vehicle parking area for the warehouse, the circulation drives, and the area for the outdoor storage of small machines. The Applicant has requested a waiver. Testimony shall be provided. Our office recommends that the Applicant shall provide adequate lighting in the rear of the site.
The lighting plan indicates that the lighting will be on timers. Testimony shall be provided.
The light pole symbol for the single fixture behind the office building to the north is not clearly shown. The utility text is not necessary on the lighting plan.
The lighting schedule indicates 2 types of lights for each symbol. The plan view should clearly label the fixtures to ensure that the correct light fixture is installed.
The Area Light Detail on sheet 11 of 23 indicates “not for construction”. A detail shall be provided for construction.
H. Storage of Solid Waste & Recyclable Materials
1. An approximately 20 ft x 10 ft refuse enclosure is proposed. Dimensions shall be provided on the site plan.
Jackson Township Planning Board Our file No. 1512-P-620
Page 12
Per §244-208E if located within or adjacent to a parking area or access drive, the enclosed refuse areas shall be separated from such parking area or access drive by curbing, whereas no curbing is proposed. The plan should be revised, or the Applicant shall request a waiver.
The refuse enclosure detail shall be revised to reflect the refuse enclosure shown on the plan. An elevation view of the trash enclosure shall be included as well as a block wall detail and gate detail.
Per $244-208K$ for every solid waste storage area, at least one area shall be designated adjacent thereto for the collection of recyclable materials. The refuse enclosure detail shall be revised to designate the areas.
The Applicant shall provide testimony to discuss the size of the trash enclosure to adequately service the all uses on the site.
The Applicant shall provide testimony as to the frequency the refuse will be removed from the site.
The Applicant should indicate the anticipated amount of recyclable materials generated for the use, how recyclable material will be collected, as well as bulk items.
The Applicant shall provide testimony to discuss if hazardous materials will be stored on-site and the method proposed to remove those materials from the site.
I. Miscellaneous
The Applicant shall address the issues identified within the Pinelands Commission's Inconsistent Certificate of Filing. As indicated on page 3 of 3, Condition 8 "items on the attached inconsistencies document must be resolved prior to Commission issuance of a letter indicating that any approvals or permits can take effect.
Our office recommends that the lots are consolidated as a condition of approval.
Legible bearings and distances shall be provided along Whitesville Road.
Per §244-189A(c) preliminary major site plan applications involving the construction of 20,000 square feet of new gross floor area shall be accompanied by an environmental impact statement, whereas none was provided. An environmental impact statement shall be provided, or the Applicant shall request a waiver. Testimony shall be provided to discuss the need for an environmental impact statement.
The Applicant shall provide testimony to discuss the potential environmental impacts as a result of the proposed development.
The tract is located in the Conservation Overlay Zone. The Applicant has delineated a wetland's buffers on the plans as approved per Pinelands #2020-0045.001 as shown on a plan titled "Environmental Constraints Plan, prepared by Professional Design Services, LLC, dated January 19, 2023." A copy of the plan shall be provided to our office.
Per §244-45C(1)(c) all wetlands, as identified and verified, pursuant to the LOI (letter of interpretation) shall be excluded from the gross acreage for purposes of calculating maximum lot coverage (building and impervious) for nonresidential developments. No wetlands are delineated on the site. Testimony shall be provided to confirm that there are no wetlands on-site.
The Applicant is required to obtain all local and outside agency approvals.
A list of any requested variances and waivers shall be provided on the plans.
Jackson Township Planning Board Our file No. 1512-P-620
Page 13
Issues related to the Affordable Housing Non-Residential Development Fee are deferred to the Board Solicitor.
Per 244-176.1G(1) office trailers may be used on a construction site as a construction office, subject to individual approval by the Planning Board or Zoning Board of Adjustment, and as individually approved by the Construction Official. Said office trailer may not be placed on the site prior to issuance of a building permit and must be removed at the owner's expense upon completion of the job. The Applicant shall provide testimony to discuss their intentions to place a temporary office trailer on-site.
Testimony should be provided regarding the earthwork quantities for the site and compliance with Chapter 364 – Soil/Fill Importation.
V. VARIANCE(S) & WAIVER(S)
A. Variance or waiver relief may be required pending Applicant's response to the issues identified in the body of this report.
Any resubmissions in response to this report should be accompanied by a point-by-point response to all items, with revisions on the plans clouded or highlighted to indicate changes. In order to facilitate the Board's decision-making process, Applicants are strongly encouraged to resolve as many items as possible prior to the hearing on this matter.
As always, Board members, Applicants and their professionals should feel free to contact me in our Toms River office if they have any questions or require additional information.
God Bless America.
REMINGTON & VERNICK ENGINEERS
Ernest J. Peters, Jr., P.E., P.P., C.M.E.
Board Planner
MMG/EJP:mr
cc: Mr. Robert Shea II, Esq. – Board Attorney
Mr. Doug Klee, P.E. – Board Engineer
ville, LLC – Applicant/Owner (vcarrev@atlanticsitenj.com)
Mr. Yosef Portnoy, P.E. - Applicant's Engineer (vportnov@civilcoreconsulting.com)
Mr. Scott T. Kennel – Applicant's Traffic Consultant (skennel@mratraffic.com)
Mr. Naftoli Gut, R.A. – Applicant's Architect (naftoli@gutvann.com)
Ms. Donna Jennings, Esq. – Applicant's Attorney (djennings@wilentz.com)
11/6/2025 Jackson Township Planning Board ATTN: Laura Morrison 95 W Veterans Hwy Jackson NJ 08527
RE: 510 Whitesville Road Block 22401, Lots 9-12 Jackson, NJ Civil Core Consulting # 23089
1969 Rutgers University Blvd, Suite 102 Lakewood NJ 08701 Phone: 732.962.9720
Dear Laura,
Per your email request for reduced size copies for the hearing for the above-mentioned site we have enclosed:
Eleven (11) copies of the Site Plan titled “Preliminary and Final Major Site Plan For Block 22401 Lots 7,8,9,10,11,12” last revised 7/31/2025 by Civil Core Consulting
Eleven (11) copies of the Site Plan titled “Preliminary and Final Major Site Plan For Block 22401 Lots 7,8,9,10,11,12 - Vehicle Circulation Plan” last revised 7/31/2025 by Civil Core Consulting
Eleven (11) copies of the Traffic Report dated 1/14/2025 by McDonough & Rea Associates
For any questions, please reach out to me at ecohen@civilcoreconsulting.com or 732-962-9720 ext.103. Thank you. Eliezer Cohen, Permit Coordinator