3 Scope of services and equipment specifications

Provide the equipment specified below. Dimensions are estimating information only. The installer must field-verify dimensions, clearances, weights, loads and compatibility before fabrication. References to manufacturers establish the specified basis of design; equivalent products require County approval by written addendum before proposals are due.

Existing characteristicRequirement to preserve
Type and quantityOne in-ground hydraulic passenger elevator; simplex operation
Rated capacity and speed3,500 lb; 125 feet per minute
Travel and stops30 ft 0 in travel; four stops
OpeningsFour front openings; no rear or side openings
Doors and entrancesPassenger; front left-hand. Width unresolved: 2023 package lists 4 ft 0 in; 2025 quote lists 3 ft 6 in. Height 7 ft 0 in. See Attachment A.
Cab layout and nominal sizeStandard cab; 6 ft 8 in × 5 ft 5 in × 8 ft 0 in
Pit accessBottom landing
Cab componentSpecified basis of design
Cab packageNew 600 Series cab package or approved equivalent stainless cab 14 ga 304 ss
Wall panelsRigidized 5WL, 14-gauge Type 304 stainless steel
Car doorsGAL; final width to match verified existing opening; nominal height 7 ft 0 in. See Attachment A.
VentilationOne Nylube X12F9
CartopCold rolled steel; cartop railing package
Ceiling and lightingCS4 stainless island; stainless ceiling panels; black lighting trim
HandrailsNo. 4 stainless rectangular hollow; 2 in high × 1/2 in thick
Bumper railsNo. 4 stainless rectangular hollow; 2 in high × 1/2 in thick