Provide the equipment specified below. Dimensions are estimating information only. The installer must field-verify dimensions, clearances, weights, loads and compatibility before fabrication. References to manufacturers establish the specified basis of design; equivalent products require County approval by written addendum before proposals are due.
| Existing characteristic | Requirement to preserve |
|---|
| Type and quantity | One in-ground hydraulic passenger elevator; simplex operation |
|---|
| Rated capacity and speed | 3,500 lb; 125 feet per minute |
|---|
| Travel and stops | 30 ft 0 in travel; four stops |
|---|
| Openings | Four front openings; no rear or side openings |
|---|
| Doors and entrances | Passenger; front left-hand. Width unresolved: 2023 package lists 4 ft 0 in; 2025 quote lists 3 ft 6 in. Height 7 ft 0 in. See Attachment A. |
|---|
| Cab layout and nominal size | Standard cab; 6 ft 8 in × 5 ft 5 in × 8 ft 0 in |
|---|
| Pit access | Bottom landing |
|---|
| Cab component | Specified basis of design |
|---|
| Cab package | New 600 Series cab package or approved equivalent stainless cab 14 ga 304 ss |
|---|
| Wall panels | Rigidized 5WL, 14-gauge Type 304 stainless steel |
|---|
| Car doors | GAL; final width to match verified existing opening; nominal height 7 ft 0 in. See Attachment A. |
|---|
| Ventilation | One Nylube X12F9 |
|---|
| Cartop | Cold rolled steel; cartop railing package |
|---|
| Ceiling and lighting | CS4 stainless island; stainless ceiling panels; black lighting trim |
|---|
| Handrails | No. 4 stainless rectangular hollow; 2 in high × 1/2 in thick |
|---|
| Bumper rails | No. 4 stainless rectangular hollow; 2 in high × 1/2 in thick |
|---|