100 West Norton Avenue • Eustis, Florida 32726 • (352) 357-6585
Tent Fire Safety Requirements (Cont.)
Means of Egress
- Number of Means of Egress (Exits) shall not be less than two with a minimum with of 6 feet for each exit.
- Means of Egress (Exits) shall be marked with exit signage.
- Illumination of Means of Egress - Means of Egress, other than for private party tents not exceeding 1200 square feet shall be illuminated.
- Emergency Lighting - Emergency lighting shall be provided. Private party tents not exceeding 1200 square feet shall not be required to have emergency lighting.
Electrical Service
- Building department permit and inspection required for the erection of temporary power poles.
- Building department permit and inspection required if new wiring is run from an existing electrical service. (Extension Cords are exempt)
- Building department permit and inspection required when using generator(s) having a 5kW rating or greater to provide power to the tent.
Fired Heaters
- The authority having jurisdiction shall approve fuel-fired heaters and their installation.
- Containers for liquefied petroleum gases shall be installed not less than 5-ft (1.5 m) from any tent and shall be in accordance with the provisions of NFPA 58, Liquefied Petroleum Gas Code.
- Tanks shall be secured in the upright position and protected from vehicular traffic.
Electric Heaters
- Heaters used inside a tent shall be UL approved and listed for such a purpose.
- Heaters shall be connected to electricity by electric cable that is suitable for outside use and is of sufficient size to handle the electrical load.