PROPOSED CHANGE OF USE AND ALTERATIONS

45 PITNEY LANE JACKSON, NJ 08527 BLOCK 21001 LOT 1

REVISIONS

BUILDING DATA EXISTING USE GROUP RESIDENTIAL (R-5)

PROPOSED USE GROUP ASSEMBLY (A-3) SEE CHANGE OF USE CHART BELOW

CONSTRUCTION TYPE PER IBC EXISTING CONSTRUCTION IS COMBUSTIBLE TYPE V-B

AUTOMATIC SPRINKLER SYSTEM PROVIDED SPRINKLER DRAWINGS BY OTHERS

PROJECT VICINITY

FIRE ALARM PROVIDED FIRE ALARM DRAWINGS BY OTHERS

BUILDING SIZE

BUILDING SIZE HEIGHT ABOVE GRADE: 24' 6" STORIES ABOVE GRADE: 2

AREA AND VOLUME

BASEMENT:3,761 SF29,366 CF
GROUND FLOOR:4,366 SF34,928 CF
2ND FLOOR:1,509 SF12,072 CF
TOTAL9,636SF76,366 CF

NOTE

THIS PROJECT IS CLASSIFIED AS "ALTERATION WORK" AS DEFINED BY THE NJ REHABILITATION SUBCODE, AND, AS SUCH, IS ONLY REQUIRED TO COMPLY WITH THE IBC TO THE EXTENT DETAILED IN NJAC §5:23-6.6. IBC COMPLIANCE DATA PROVIDED IS AS PER IBC REQUIREMENTS FOR NEW CONSTRUCTION AND ARE PROVIDED FOR REFERENCE ONLY.

ITEMCODE REFERENCEEXISTINGCATEGORYPROPOSEDCATEGORYCHANGE TO HIGHER CATEGORYNOTES
RELATIVE GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE BR-55A-34YESTHE BUILDING HAS BEEN ALTERED TO COMPLY WITH THE BASIC REQUIREMENTS FOR OCCUPANCY A-3
MEANS OF EGRESS GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE CR-54A-33YESTHE BUILDING HAS BEEN ALTERED TO COMPLY WITH THE SPECIFIED REQUIREMENTS OF THE BUILDING SUBCODE (N.J.A.C 5:23-6.31 TABLE C (2))
HEIGHT AND AREA GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE ER-54A-32YESTHE BUILDING HAS BEEN REVIEWED AND COMPLIES WITH THE SPECIFIED REQUIREMENTS OF CHAPTER 5 OF THE BUILDING SUBCODE. (NJ EDITION OF IBC 2021) NO CHANGE IS REQ'D.
EXTERIOR WALL EXPOSURE GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE FR-54A-33YESTHE BUILDING HAS BEEN REVIEWED AND COMPLIES WITH THE SPECIFIED REQUIREMENTS OF CHAPTER 5 OF THE BUILDING SUBCODE BUILDING SUBCODE (N.J.A.C 5:23-6.31 TABLE F (1)) NO
AUTOMATIC SPRINKLER SYSTEM GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE GR-56A-35YESTHE BUILDING HAS BEEN ALTERED TO COMPLY WITH THE SPECIFIED REQUIREMENTS OF 903.2.1 OF THE BUILDING SUBCODE (NJ EDITION OF IBC 2021)
STRUCTURAL LOADS GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE KR-53A-32YESTHE BUILDING HAS BEEN ALTERED TO COMPLY WITH THE SPECIFIED REQUIREMENTS OF THE TABLE 1607.1 OF THE BUILDING CODE (NJ EDITION OF IBC 2021)

CODES

ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH:

  • THE NEW JERSEY EDITION OF THE INTERNATIONAL BUILDING CODE 2021 EDITION
  • NJUCC REHAB CODE
  • NATIONAL STANDARD PLUMBING CODE 2021
  • NATIONAL ELECTRIC CODE 2020
  • ASHRAE 90.1-2019
  • INTERNATIONAL MECHANICAL CODE 2021
  • INTERNATIONAL FUEL GAS CODE 2021
  • AMERICAN CONCRETE INSTITUTE ACI 318-14
  • ICC/ANSI A117.1-2017
  • OSHA AND ADA REQUIREMENTS & ANY OTHER APPLICABLE STATE, FEDERAL & LOCAL CODES, LAWS, REGULATIONS & REQUIREMENTS, WHICH SHALL TAKE PRECEDENCE OVER ANYTHING NOTED ON THESE DRAWINGS.

3/10/2026 10:57:58 AM

SHEET SCHEDULE
SHEETDESCRIPTION
CS1COVER SHEET
A1EXISTING PLANS - BASEMENT AND FIRST FLOOR
A2EXISTING PLANS - SECOND FLOOR
A3DEMO PLANS - BASEMENT AND FIRST FLOOR
A4DEMO PLANS - SECOND FLOOR
A5FOUNDATION PLAN
A6CONSTRUCTION PLAN - FIRST FLOOR
A7CONSTRUCTION PLAN - SECOND FLOOR
A8ELEVATIONS
A9ELEVATIONS

GutVann ARCHITECTURE

FOR ZONING USE ONLY. NOT FOR CONSTRUCTION

45 PITNEY LANE JACKSON, NJ 08527 BLOCK 21001 LOT 1

CONSULTANTS:

NJ C.O.A. #: 21AC00125800 1999 CEDARBRIDG AVE 4TH FLOOR LAKEWOOD, NJ 08701 732-806-0073 | office@gutvann.com

SIGNATURE & SEAL

PROJECT PROPOSED CHANGE OF USE AND ALTERATIONS

NAFTOLI GUT, R.A. NJ LICENSE #: 21AI02127300 NY LICENSE #: 041823

DRAWING COVER SHEET

DATE: 1.21.26 SCALE: $ 1/4" = 1'-0" $ JOB NUMBER: 25-707

DRAWN: RW CHECKED: NG

CS1