PROPOSED CHANGE OF USE AND ALTERATIONS
45 PITNEY LANE JACKSON, NJ 08527 BLOCK 21001 LOT 1
REVISIONS
BUILDING DATA EXISTING USE GROUP RESIDENTIAL (R-5)
PROPOSED USE GROUP ASSEMBLY (A-3) SEE CHANGE OF USE CHART BELOW
CONSTRUCTION TYPE PER IBC EXISTING CONSTRUCTION IS COMBUSTIBLE TYPE V-B
AUTOMATIC SPRINKLER SYSTEM PROVIDED SPRINKLER DRAWINGS BY OTHERS
PROJECT VICINITY
FIRE ALARM PROVIDED FIRE ALARM DRAWINGS BY OTHERS
BUILDING SIZE
BUILDING SIZE HEIGHT ABOVE GRADE: 24' 6" STORIES ABOVE GRADE: 2
AREA AND VOLUME
BASEMENT:3,761 SF29,366 CF
GROUND FLOOR:4,366 SF34,928 CF
2ND FLOOR:1,509 SF12,072 CF
TOTAL9,636SF76,366 CF
NOTE
THIS PROJECT IS CLASSIFIED AS "ALTERATION WORK" AS DEFINED BY THE NJ REHABILITATION SUBCODE, AND, AS SUCH, IS ONLY REQUIRED TO COMPLY WITH THE IBC TO THE EXTENT DETAILED IN NJAC §5:23-6.6. IBC COMPLIANCE DATA PROVIDED IS AS PER IBC REQUIREMENTS FOR NEW CONSTRUCTION AND ARE PROVIDED FOR REFERENCE ONLY.
ITEMCODE REFERENCEEXISTINGCATEGORYPROPOSEDCATEGORYCHANGE TO HIGHER CATEGORYNOTES
RELATIVE GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE BR-55A-34YESTHE BUILDING HAS BEEN ALTERED TO COMPLY WITH THE BASIC REQUIREMENTS FOR OCCUPANCY A-3
MEANS OF EGRESS GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE CR-54A-33YESTHE BUILDING HAS BEEN ALTERED TO COMPLY WITH THE SPECIFIED REQUIREMENTS OF THE BUILDING SUBCODE (N.J.A.C 5:23-6.31 TABLE C (2))
HEIGHT AND AREA GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE ER-54A-32YESTHE BUILDING HAS BEEN REVIEWED AND COMPLIES WITH THE SPECIFIED REQUIREMENTS OF CHAPTER 5 OF THE BUILDING SUBCODE. (NJ EDITION OF IBC 2021) NO CHANGE IS REQ'D.
EXTERIOR WALL EXPOSURE GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE FR-54A-33YESTHE BUILDING HAS BEEN REVIEWED AND COMPLIES WITH THE SPECIFIED REQUIREMENTS OF CHAPTER 5 OF THE BUILDING SUBCODE BUILDING SUBCODE (N.J.A.C 5:23-6.31 TABLE F (1)) NO
AUTOMATIC SPRINKLER SYSTEM GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE GR-56A-35YESTHE BUILDING HAS BEEN ALTERED TO COMPLY WITH THE SPECIFIED REQUIREMENTS OF 903.2.1 OF THE BUILDING SUBCODE (NJ EDITION OF IBC 2021)
STRUCTURAL LOADS GROUP/ HAZARDN.J.A.C. 5:23-6.31 TABLE KR-53A-32YESTHE BUILDING HAS BEEN ALTERED TO COMPLY WITH THE SPECIFIED REQUIREMENTS OF THE TABLE 1607.1 OF THE BUILDING CODE (NJ EDITION OF IBC 2021)
CODES
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH:
THE NEW JERSEY EDITION OF THE INTERNATIONAL BUILDING CODE 2021 EDITION
NJUCC REHAB CODE
NATIONAL STANDARD PLUMBING CODE 2021
NATIONAL ELECTRIC CODE 2020
ASHRAE 90.1-2019
INTERNATIONAL MECHANICAL CODE 2021
INTERNATIONAL FUEL GAS CODE 2021
AMERICAN CONCRETE INSTITUTE ACI 318-14
ICC/ANSI A117.1-2017
OSHA AND ADA REQUIREMENTS & ANY OTHER APPLICABLE STATE, FEDERAL & LOCAL CODES, LAWS, REGULATIONS & REQUIREMENTS, WHICH SHALL TAKE PRECEDENCE OVER ANYTHING NOTED ON THESE DRAWINGS.
3/10/2026 10:57:58 AM
SHEET SCHEDULE
SHEETDESCRIPTION
CS1COVER SHEET
A1EXISTING PLANS - BASEMENT AND FIRST FLOOR
A2EXISTING PLANS - SECOND FLOOR
A3DEMO PLANS - BASEMENT AND FIRST FLOOR
A4DEMO PLANS - SECOND FLOOR
A5FOUNDATION PLAN
A6CONSTRUCTION PLAN - FIRST FLOOR
A7CONSTRUCTION PLAN - SECOND FLOOR
A8ELEVATIONS
A9ELEVATIONS
GutVann ARCHITECTURE
FOR ZONING USE ONLY. NOT FOR CONSTRUCTION
45 PITNEY LANE JACKSON, NJ 08527 BLOCK 21001 LOT 1
CONSULTANTS:
NJ C.O.A. #: 21AC00125800 1999 CEDARBRIDG AVE 4TH FLOOR LAKEWOOD, NJ 08701 732-806-0073 | office@gutvann.com
SIGNATURE & SEAL
PROJECT PROPOSED CHANGE OF USE AND ALTERATIONS
NAFTOLI GUT, R.A. NJ LICENSE #: 21AI02127300 NY LICENSE #: 041823
DRAWING COVER SHEET
DATE: 1.21.26 SCALE: $ 1/4" = 1'-0" $ JOB NUMBER: 25-707
DRAWN: RW CHECKED: NG
CS1