right-of-way dedication.
Per §244-47E(4)(b) The minimum lot depth is 200 ft, whereas 190.07 ft is existing.
Per §244-197N(1) the minimum parking spaces required is 52 parking spaces, whereas 37 parking spaces are provided (including 5 EV credited spaces). The Applicant has requested a variance.
With the exception of the following, site plan issues are deferred to the Board Engineer.
The Applicant shall provide testimony to discuss the intensity of the development and the number of waivers/variance necessary for the proposed development.
The Applicant shall discuss the uses of each room within the building and rectify these uses with those permitted within the zone. Our office recommends that common names or terms for each room be provided for clarity.
The Applicant shall provide testimony to discuss the proposed activities and anticipated participants, a timetable reflecting the hours which the building will be used, and any other pertinent uses and activities intended to take place on the site.
The Applicant shall provide testimony to discuss the proposed operations for the proposed use in sufficient detail to indicate the effects of the use in producing traffic congestion, noise, glare, air pollution, fire hazards or safety hazard, the hours of operation of the use, the number of shifts to be worked, the number of employees in each shift, number of congregants, the number of vehicles to be stored or parked on the site and provisions to be made for site maintenance.
The Applicant shall provide testimony to discuss the square footage of each floor of the building. The building square footages shown on the architectural plans should be verified on the site plans for consistency.
The Applicant shall provide testimony to discuss the proposed interior renovations.
The Applicant shall provide testimony to discuss if any exterior renovations are proposed.
Our office recommends that solar be incorporated into the building/site design.
Per §244-207B(7)(a) each principal nonresidential building may have one wall sign not to exceed 15% of the principal facade area or 80 square feet, whichever is smaller. The Applicant shall provide testimony to indicate if any wall signage is proposed. If wall signage is proposed, a detail shall be provided to determine compliance.
The Applicant shall provide testimony to verify that no freestanding/monument signage is proposed.
1. Per §244-47E(1) lots shall not have their sole frontage on a residential access or residential neighborhood street or any lower order street, as defined by the Residential Site Improvement