S University Dr.
Frankfort, KY 40601
CONSTRUCTION
DOCUMENTS
REVISIONS
# DATE DESCRIPTION
architecture | interiors
EOP Architects
Prime Architect
201 W. Short Street, Suite 700
Lexington, KY 40507
p. 859-231-7538 | f. 859-255-4380
www.eopa.com
Brown + Kubican, PSC
Structural Engineer
2224 Young Drive
Lexington, KY 40505
p. 859.543.0933
www.brownkubican.net
CARMAN
Landscape Architect
310 Old Vine Street, Suite 200
Lexington, KY 40507
p. 859.254.9803
www.carmansite.com
Staggs & Fisher
MEP Engineer
3264 Loch Ness Drive,
Lexington, KY 40517
p. 859.271.3246
www.sfengineering.com
All designs, arrangements and plans indicated or represented by this drawing are the property of EOP Architects and were created and developed for use on and in connection with the specified project.
5/24/2021 11:26:46 AM
INDICATES AREA THAT WILL BE PART OF
A FUTURE FIT-UP PHASE. CODE AND
EGRESS INFORMATION TO BE INCLUDED
IN FUTURE PLAN SUBMITTALS
LEVEL 0 - 737 / 16,540 GSF *Occupant load to be updated within Fit-Up package.*
LEVEL 1 - 604 / 29,980 GSF
LEVEL 2 - 449 / 29,590 GSF
LEVEL 3 - 484 / 29,590 GSF
LEVEL 4 - 484 / 29,590 GSF
LEVEL 5 - 484 / 29,590 GSF
ROOF = 24,826 SF (OPEN)
PENTHOUSE = 4,882 SF (ENCLOSED)
LEVEL 0: 737 / 5 EXITS = 147.4 * 0.15 = 22.22" (32" MIN. CLEAR PROVIDED AT EACH EXIT)
LEVEL 1: 604 / 4 EXITS = 151.0 * 0.15 = 22.65" (32" MIN. CLEAR PROVIDED AT EACH EXIT)
LEVEL 2: 449 / 3 EXITS = 149.7 * 0.15 = 22.45" (32" MIN. CLEAR PROVIDED AT EACH EXIT)
LEVEL 3: 484 / 3 EXITS = 161.4 * 0.15 = 24.20" (32" MIN. CLEAR PROVIDED AT EACH EXIT)
LEVEL 4: 484 / 3 EXITS = 161.4 * 0.15 = 24.20" (32" MIN. CLEAR PROVIDED AT EACH EXIT)
LEVEL 5: 484 / 3 EXITS = 161.4 * 0.15 = 24.20" (32" MIN. CLEAR PROVIDED AT EACH EXIT)
A
| Job Number | 1909 | PLAN |
|---|
| Drawn By | KF | TRUE |
|---|
| Checked By | MPS | |
|---|
| Date | MAY 24, 2021 |
|---|
Written dimensions shall have precedence over scale dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job. Notify EOP Architects immediately of any variation from the dimensions and conditions shown by these drawings.
None of this information shall be used by or
disclosed to any person or entity for any reason
whatsoever without the permission of EOP
Architects.
ALL COORIDORS TO BE RATED 1/2 HOUR, REFER TO PLAN FOR 1/2 HOUR RATED WALLS.
ALL RESIDENT ROOMS TO BE SEPARATED BY 1/2 HOUR RATING FROM OTHER RESIDENT ROOMS AND ANY OTHER NON-RESIDENTIAL SPACES.