Company Name: Kentucky State University Quote Number: SSI-227769-C8R2 Activation Date: 5/15/2023 Expiration Date: 6/30/2023
Sturdy polyethylene waste can with a solvent vapor filter and tubing manifold to accept waste from 1 autosampler and 1 detector. Additional fittings to allow multiple systems to feed one waste can are sold separately. For reversed-phase solvents only. Use 220-91442-00 (2 gal) or 220-91443-00 (5 gal) for normal phase solvents.
Tubing manifold and vapor filter attach to the can with a polypropylene quick-disconnect fitting for ease of emptying and vapor filter replacement. Because polypropylene swells when exposed to THF, chloroform, hexane, heptane, etc. this can is not recommended for normal phase solvents.
220-91524-15 Column, LC, Shodex IC SI-90 4E, Column, Anion suppressed, 9um, 4.0 x 250mm
Shodex IC SI-90 4E Anion column for suppressed IC. 9μm, 4 x 250mm. Guard column SI-90G 220-91524-05 and coupler 220-91524-99 are recommended.
220-91524-05 Column, LC, Shodex IC SI-90G, Guard Column, Anion suppressed, 9um, 4.6 x 10mm
Anion analysis guard column for suppressed IC, 4.6 x 10mm. Use with SI-90 4E Anion analytical column 220-91524-15. Requires PEEK coupler 220-91524-99.
Shodex SI-90G
220-91524-06 Column, LC, Shodex IC YS-50 Cation 5 micron, 4.6 x 125mm
The IC YS-50 column has a carboxyl functional group on silica base material, used for non-suppressed cation separations. It is especially effective for simultaneous analysis of mono- and divalent cations, for alkyl amines and for good separation of sodium. Product Base Material: Polyvinyl Alcohol Product Functional group: Carboxyl Product In-column solvent: H2O Product Max. Pressure (MPa): 15 Product Max. Usable Flow Rate (mL/min): 2.0 Product Particle size, um: 5 Product Plate number (TP/Column): >5,500 Product Scope of application: Simultaneous separation of monovalent and divalent cations Product Size (I.D. x Length, mm): 4.6 x 125 Product Temperature Range (\circC): 20 - 60 Product Type: Cation
220-91524-07 Column, LC, Shodex IC YS-G Cation Guard 5 micron, 4.6 x 10mm
Shodex IC YS-G Guard column for Shodex IC YS-50 cation analysis column Shodex IC YS-G Guard column for Shodex IC YS-50 cation analysis column
228-31537-91 Vials, LC, 4mL Plastic, 100/pk.
Polypropylene, 15 x 48 mm. For SIL-10ADvp Racks 3 and 13, and for LC-2010, SIL-HT, and SIL-20 rack for 4.0 mL vials. 100 pcs./set 4mL Polypropylene vial set. Quantity 100 w/caps and silicone septa.
220-97330-80 Syringes, Syrfi Disposable Syringes, Plastic, Luer-lock, 3 mL, 100/pk
3mL syringe with polyethylene barrel and polypropylene plunger. The Luer lock outlet is compatible with any Syrfi syringe filter and provides a secure fit when filtering viscous or high particulate samples.
220-97330-75 Syringe Filters, Syrfi Syringe Filters, 25MM 0.45UM POLYETHERSULFONE, 100/pk
The polyether sulfone (PES) membrane is the best choice for ion chromatography (IC) applications, due to certification by ICP for low-level interferences.
Filter inlet can be connected to either a Luer slip or lock syringe. Filter outlet can accommodate a Luer slip needle or other connector. Polypropylene housing, 25mm diameter, 0.45um membrane, 100/pk. Not compatible with aqueous protein based samples, concentrated acids, dichloromethane, chloroform, hexane, acetone, MEK. Polypropylene sample vials are recommended for IC applications.
220-95315-05 HPLC Virtual Advisor USB for Prominence and Nexera Systems
HPLC Virtual Advisor for Prominence, Nexera and i-Series Systems. Stock card with information about Virtual Advisor and links to the websites for current advisors. HPLC Virtual Advisor for Prominence, Nexera and i-Series Systems. Stock card with information about Virtual Advisor and links to the websites for current advisors. There is also a coupon for 10% off in the Webstore.
220-91545-01 Solvents, LC, Honeywell B&J LCMS Grade Solvent Kit for Installations