A - FLAG COLUMN SIGN - QTY 1 - SqFt: 12
ALL ELECTRICAL COMPONENTS WILL BE ETL LISTED AND LABELED AS PER NEC ARTICLE 600 & DESIGNED TO CONFORM TO UL #48 PER F.S.553-19. ALL SIGNS ARE TO BE GROUNDED AND BONDED PER NEC 250. ALL WIRING INSIDE LETTER WILL BE 12V-CLASS 2 18GA/LOW VOLTAGE WIRING. ALL PRIMARY WIRING WILL BE (3) #12 CU THWN AS PER NEC ARTICLE 600. JUCTION BOX INSTALLED BY CUSTOMER'S ELECTRICAL CONTRACTOR TO WITHING 6' OF SIGN LOCATION. HVHZ 1620 WITH WIND LOADS PER ASCE 7-10. ETL APPROVED, WEATHERPROOF, 20 AMP ELECTRICAL SERVICE DISCONNECT SWITCH ASPER NEC ARTICLE 600, CONNECT TO PHOTOCELL AND/OR ASTRONOMICAL TIME CLOCK.
DESIGN, FABRICATION AND CONSTRUCTION TO THE FOLLOWING:
THE FLORIDA BUILDING CODE 5th EDITION (2014)
AMERICAN WELDING SOCIETY AWS D1.1-04 & D1.2
AMERICAN CONCRETE INSTITUTE BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 318-11.
STRUCTURAL STEEL REQUIREMENTS:
PLATES, ROLLED SHAPES AND BARS SHALL BE ASTM A36, OR EQUAL
STANDARD PIPE SHALL BE ASTM A53, GRADE B OR EQUAL (FY=35 KSI)
STRUCTURAL TUBING SHALL BE ASTM A500, GRADE B OR EQUAL (FY=46 KSI)
ALL BOLTED CONNECTIONS SHALL BE MADE WITH ASTM A307 BOLT OR EQUAL
ALL ANCHOR BOLTS SHALL BE ASTM A307 OR EQUAL (FLAT WASHERS)
ALL WELDS SHALL BE MADE WITH E70XX ELECTRODES OR EQUAL
STRUCTURAL STEEL SHALL BE SHOP PRIME COATED WITH RUST INHIBITIVE PRIME
NEC 2011 COMPLIANT
ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSION STRENGTH AT 28 DAYS/3000 PSI
GROUT SHALL BE NON-METALLIC AND NON-SHRINK WITH MINIMUM COMPREHENSIVE STRENGTH OF 5000 PSI AT ONE DAY
ALL REINFORCED STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PS AND SHALL CONFORM TO ASTM A615
ALL REINFORMED STEEL SHALL BE INSTALLED IN ACCORDANCE WITH ACI 318-WITH A MINIMUM CONCRETE COVER OF 3 INCHES
H.V.H.Z. SECTION 1620 F.B.C., ASCE 7-10 175 MPH, EXPOSURE C, CATERGORY 2, CHAPTER 16.
ALL FERROUS TO NON FERROUS SURFACES SHALL BE SEPARATED BY 3M #355 POLYESTER CLEAR TAPE OR EQUAL
project name:
Planet Fitness - Fort Lauderdale
project address:
110 SE 6th St.
Fort Lauderdale, FL 33301
10/06/25
scope of work:
Exterior Signage
client
notes
ALL ELECTRIC SIGNS ARE
UL LISTED AND LABELED
All designs, renderings, and concepts produced by SignWorks are the intellectual property of our company and are not to be used, shared, or manufactured by any other company without our written consent. These designs are created exclusively for our clients with the intent of being fabricated and installed by SignWorks.
COLORS SHOWN ON DRAWINGS ARE FOR PRESENTATION PURPOSES ONLY. ALL COLORS MUST BE CONFIRMED AND INITIALED BY PROJECT MANAGER PRIOR FABRICATION
The enclosed renderings, concepts, branded images, color representations, layouts, wording and all aspects of this design / presentation remain the exclusive property of SIGNWORKS BOCA and may not be shared, copied, duplicated in any way shape or manner without the permission of SIGNWORKS BOCA. Any unauthorized reproduction, duplication in any way, shape or fashion will constitute trade infringement and will be subject to recovery of lost revenue under Florida law.
3.0