Scenario: PD&E
From Node: 104
To Node: 102
Link Count: 1
Flow Direction: Both
Damping: 0.0000 ft
Weir Type: Paved Road Vertical
Geometry Type: Irregular
Invert: 51.30 ft
Control Elevation: 51.30 ft
Cross Section: X-104-102
306
Bottom Clip
Default: 0.00 ft
Op Table:
Ref Node:
Top Clip
Default: 0.00 ft
Op Table:
Ref Node:
Discharge Coefficients
Weir Default: 2.800
Weir Table:
Orifice Default: 0.600
Orifice Table:
Scenario: PD&E
From Node: 104
To Node: 102D
Link Count: 1
Flow Direction: Both
Damping: 0.0000 ft
Weir Type: Broad Crested Vertical
Geometry Type: Irregular
Invert: 51.03 ft
Control Elevation: 51.03 ft
Cross Section: X-104-102D
Bottom Clip
Default: 0.00 ft
Op Table:
Ref Node:
Top Clip
Default: 0.00 ft
Op Table:
Ref Node:
Discharge Coefficients
Weir Default: 2.800
Weir Table:
Orifice Default: 0.600
Orifice Table:
Scenario: PD&E
From Node: 105
To Node: 110
Link Count: 1
Flow Direction: Both
Damping: 0.0000 ft
Weir Type: Broad Crested Vertical
Geometry Type: Irregular
Invert: 51.27 ft
Control Elevation: 51.27 ft
Cross Section: X-105-110
Bottom Clip
Default: 0.00 ft
Op Table:
Ref Node:
Default: 0.00 ft
Op Table:
Ref Node:
Discharge Coefficients
Weir Default: 2.800
Weir Table:
Orifice Default: 0.600