297
| Bend Loss Coef: | 0.00 | Default: | 0.00 ft | Default: | 0.00 ft |
|---|---|---|---|---|---|
| Bend Location: | 0.00 dec | Op Table: | Op Table: | ||
| Energy Switch: | Energy | Ref Node: | Ref Node: | ||
| Manning's N: | 0.0000 | Manning's N: | 0.0000 | ||
| Comment: Pipe size,material, and inverts are updated based on SR 70 survey (APR2022). Entr.& Exit loss coefficients updated | |||||
| Pipe Link: P-607-200 | Upstream | Downstream | |||
|---|---|---|---|---|---|
| Scenario: PD&E | Invert: 50.80 ft | Invert: 50.70 ft | |||
| From Node: 607 | Manning's N: 0.0220 | Manning's N: 0.0220 | |||
| To Node: 200 | Geometry: Circular | Geometry: Circular | |||
| Link Count: 1 | Max Depth: 1.50 ft | Max Depth: 1.50 ft | |||
| Flow Direction: Both | Bottom Clip | ||||
| Damping: 0.0000 ft | Default: 0.00 ft | Default: 0.00 ft | |||
| Length: 40.00 ft | Op Table: | Op Table: | |||
| FHWA Code: 6 | Ref Node: | Ref Node: | |||
| Entr Loss Coef: 0.20 | Manning's N: 0.0000 | Manning's N: 0.0000 | |||
| Exit Loss Coef: 1.00 | Top Clip | ||||
| Bend Loss Coef: 0.00 | Default: 0.00 ft | Default: 0.00 ft | |||
| Bend Location: 0.00 dec | Op Table: | Op Table: | |||
| Energy Switch: Energy | Ref Node: | Ref Node: | |||
| Manning's N: 0.0000 | Manning's N: 0.0000 | ||||
| Comment: Field Visit: Pipe Size estimated; Inverts estimated from DEM | |||||
| Pipe Link: P-607-600 | Upstream | Downstream | ||||
| Scenario: | PD&E | Invert: | 51.50 ft | Invert: | 51.40 ft | |
|---|---|---|---|---|---|---|
| From Node: | 607 | Manning's N: | 0.0220 | Manning's N: | 0.0220 | |
| To Node: | 600 | Geometry: | Circular | Geometry: | Circular | |
| Link Count: | 1 | Max Depth: | 1.50 ft | Max Depth: | 1.50 ft | |
| Flow Direction: | Both | Bottom Clip | ||||
| Damping: | 0.0000 ft | Default: | 0.00 ft | Default: | 0.00 ft | |
| Length: | 40.00 ft | Op Table: | Op Table: | |||
| FHWA Code: | 4 | Ref Node: | Ref Node: | |||
| Entr Loss Coef: | 0.50 | Manning's N: | 0.0000 | Manning's N: | 0.0000 | |
| Exit Loss Coef: | 0.00 | Top Clip | ||||
| Bend Loss Coef: | 0.00 | Default: | 0.00 ft | Default: | 0.00 ft | |
| Bend Location: | 0.00 dec | Op Table: | Op Table: | |||
| Energy Switch: | Energy | Ref Node: | Ref Node: | |||
| Comment: Field Visit; Pipe Size estimated; Inverts estimated from DEM | Manning's N: | 0.0000 | Manning's N: | 0.0000 | ||
Pipe Link: P-609-404 Upstream Downstream
Scenario: PD&E Invert: 48.60 ft Invert: 48.50 ft