Scenario: Existing
From Node: 102B
To Node: 102
Link Count: 1
Flow Direction: Both
Damping: 0.0000 ft
Weir Type: Broad Crested Vertical
Geometry Type: Irregular
Invert: 49.40 ft
Control Elevation: 49.40 ft
Cross Section: X-102B-102
231
Bottom Clip
Default: 0.00 ft
Op Table:
Ref Node:
Top Clip
Default: 0.00 ft
Op Table:
Ref Node:
Discharge Coefficients
Weir Default: 2.800
Weir Table:
Orifice Default: 0.600
Orifice Table:
Scenario: Existing
From Node: 102C
To Node: 102
Link Count: 1
Flow Direction: Both
Damping: 0.0000 ft
Weir Type: Broad Crested Vertical
Geometry Type: Irregular
Invert: 50.38 ft
Control Elevation: 50.38 ft
Cross Section: X-102C-102
Bottom Clip
Default: 0.00 ft
Op Table:
Ref Node:
Top Clip
Default: 0.00 ft
Op Table:
Ref Node:
Discharge Coefficients
Weir Default: 2.800
Weir Table:
Orifice Default: 0.600
Orifice Table:
Scenario: Existing
From Node: 102C
To Node: 102B
Link Count: 1
Flow Direction: Both
Damping: 0.0000 ft
Weir Type: Broad Crested Vertical
Geometry Type: Irregular
Invert: 51.46 ft
Control Elevation: 51.46 ft
Cross Section: X-102C-102B
Bottom Clip
Default: 0.00 ft
Op Table:
Ref Node:
Default: 0.00 ft
Op Table:
Ref Node:
Discharge Coefficients
Weir Default: 2.800
Weir Table:
Orifice Default: 0.600