Input Report
Pipe Link: P-101-TW-SouthUpstreamDownstream
Scenario:ExistingInvert:52.50 ftInvert:52.00 ft
From Node:101Manning's N:0.0120Manning's N:0.0120
To Node:TW-southGeometry: CircularGeometry: Circular
Link Count:1Max Depth:1.50 ftMax Depth:1.50 ft
Flow Direction:BothBottom Clip
Damping:0.0000 ftDefault:0.00 ftDefault:0.00 ft
Length:230.00 ftOp Table:Op Table:
FHWA Code:5Ref Node:Ref Node:
Entr Loss Coef:0.70Manning's N:0.0000Manning's N:0.0000
Exit Loss Coef:0.00Top Clip
Bend Loss Coef:0.00Default:0.00 ftDefault:0.00 ft
Bend Location:0.00 decOp Table:Op Table:
Energy Switch:EnergyRef Node:Ref Node:
Comment: Visible from Google Earth: Pine size and inverts assumedManning's N:0.0000Manning's N:0.0000
213
Comment: Visible from Google Earth; Pipe size and inverts assumed
Pipe Link: P-102A-207UpstreamDownstream
Scenario:ExistingInvert:48.19 ftInvert:48.11 ft
From Node:102AManning's N:0.0120Manning's N:0.0120
To Node:207Geometry: CircularGeometry: Circular
Link Count:1Max Depth:1.50 ftMax Depth:1.50 ft
Flow Direction:BothBottom Clip
Damping:0.0000 ftDefault:0.00 ftDefault:0.00 ft
Length:39.00 ftOp Table:Op Table:
FHWA Code:5Ref Node:Ref Node:
Entr Loss Coef:0.70Manning's N:0.0000Manning's N:0.0000
Exit Loss Coef:0.00Top Clip
Bend Loss Coef:0.00Default:0.00 ftDefault:0.00 ft
Bend Location:0.00 decOp Table:Op Table:
Energy Switch:EnergyRef Node:Ref Node:
Manning's N:0.0000Manning's N:0.0000
Comment: From Survey
Joe Link: P-102C-102BUpstreamDownstream
Scenario:ExistingInvert:50.31 ftInvert:50.19 ft
From Node:102CManning's N:0.0220Manning's N:0.0220
To Node:102BGeometry: CircularGeometry: Circular
Link Count:1Max Depth:1.50 ftMax Depth:1.50 ft
Flow Direction:BothBottom Clip
Damping:0.0000 ftDefault:0.00 ftDefault:0.00 ft
Length:32.00 ftOp Table:Op Table:
FHWA Code:5Ref Node:Ref Node:
Entr Loss Coef:0.70Manning's N:0.0000Manning's N:0.0000
Exit Loss Coef:0.00Top Clip
5/16/2023 17:34