211

Comment: From Survey; Existing Cross Drain

Pipe Link: EX-2UpstreamDownstream
Scenario:ExistingInvert:17.63 ftInvert:17.80 ft
From Node:302Manning's N:0.0120Manning's N:0.0120
To Node:305Geometry: CircularGeometry: Circular
Link Count:1Max Depth:2.50 ftMax Depth:2.50 ft
Flow Direction:BothBottom Clip
Damping:0.0000 ftDefault:0.00 ftDefault:0.00 ft
Length:63.00 ftOp Table:Op Table:
FHWA Code:1Ref Node:Ref Node:
Entr Loss Coef:0.50Manning's N:0.0000Manning's N:0.0000
Exit Loss Coef:0.00Top Clip
Bend Loss Coef:0.00Default:0.00 ftDefault:0.00 ft
Bend Location:0.00 decOp Table:Op Table:
Energy Switch:EnergyRef Node:Ref Node:
Manning's N:0.0000Manning's N:0.0000

Comment: From Survey; Existing Side Drain

Joe Link: EX-3_1UpstreamDownstream
Scenario:ExistingInvert:19.22 ftInvert:19.01 ft
From Node:402Manning's N:0.0120Manning's N:0.0120
To Node:407Geometry:CircularGeometry:Circular
Link Count:1Max Depth:2.00 ftMax Depth:2.00 ft
Flow Direction:BothBottom Clip
Damping:0.0000 ftDefault:0.00 ftDefault:0.00 ft
Length:76.00 ftOp Table:Op Table:
FHWA Code:1Ref Node:Ref Node:
Entr Loss Coef:0.50Manning's N:0.0000Manning's N:0.0000
Exit Loss Coef:0.00Top Clip
Bend Loss Coef:0.00Default:0.00 ftDefault:0.00 ft
Bend Location:0.00 decOp Table:Op Table:
Energy Switch:EnergyRef Node:Ref Node:
Manning's N:0.0000Manning's N:0.0000

Comment: From Survey

Pipe Link: EX-3_2UpstreamDownstream
Scenario: ExistingInvert: 19.16 ftInvert: 19.17 ft
From Node: 402Manning's N: 0.0120Manning's N: 0.0120
To Node: 407Geometry: CircularGeometry: Circular
Link Count: 1Max Depth: 2.00 ftMax Depth: 2.00 ft
Flow Direction: BothBottom Clip

5/16/2023 17:34