167
| Stage [ft] | Area [ac] | Area [ft2] |
|---|---|---|
| 52.00 | 0.8523 | 37125 |
| 52.50 | 0.9194 | 40050 |
| 53.00 | 0.9519 | 41465 |
| 53.50 | 0.9735 | 42404 |
| 54.00 | 0.9795 | 42668 |
| 54.50 | 0.9795 | 42668 |
| 39.58 | 0.0001 | 4 |
Comment: Initial stage matches pipe invert S-1; Warning Stage set at existing low edge of pavement; Roadside ditch
Node: 300
Scenario: PD&E Type: Stage/Area Base Flow: 0.00 cfs Initial Stage: 19.00 ft Warning Stage: 26.00 ft
Warning Stage: 26.00 ft
| Stage [ft] | Area [ac] | Area [ft2] |
|---|---|---|
| 17.92 | 0.0006 | 25 |
| 18.00 | 0.0008 | 34 |
| 18.50 | 0.0049 | 212 |
| 19.00 | 0.0253 | 1100 |
| 19.50 | 0.0723 | 3150 |
| 20.00 | 0.3398 | 14800 |
| 20.50 | 5.9607 | 259650 |
| 21.00 | 8.6375 | 376250 |
| 21.50 | 9.6970 | 422400 |
| 22.00 | 10.2095 | 444725 |
| 22.50 | 10.6313 | 463100 |
| 23.00 | 11.0474 | 481225 |
| 23.50 | 11.5077 | 501275 |
| 24.00 | 11.9152 | 519025 |
| 24.50 | 12.3347 | 537300 |
| 25.00 | 12.7393 | 554925 |
| 25.50 | 13.1095 | 571050 |
| 26.00 | 13.4171 | 584450 |
| 26.50 | 13.7253 | 597875 |
| 27.00 | 14.0484 | 611950 |
| 27.50 | 14.3761 | 626225 |
| 28.00 | 14.6792 | 639425 |
| 28.50 | 14.9736 | 652250 |
| 29.00 | 15.2324 | 663525 |
| 29.50 | 15.4884 | 674675 |
| 30.00 | 15.7432 | 685775 |
| 30.50 | 15.9389 | 694300 |
| 31.00 | 16.1450 | 703275 |