✓ METERS CANNOT BE INSTALLED IN CRAWL SPACES, BEHIND APPLIANCES, HOT WATER HEATERS OR FURNACES ✓ THERE MUST BE A MINIMUM CLEARANCE OF 12" ON EACH SIDE OF THE METER AND A MAXIMUM OF 36" ABOVE THE FLOOR.
☐ IN ADVANCE OF THE PROJECTED INSTALLATION DATE, CONTACT CUSTOMER SERVICE:
AN APPLICATION FOR SERVICE MUST BE COMPLETED.
APPLICABLE CONNECTION FEES MUST BE PAID IN ACCORDANCE WITH THE CURRENT 'SCHEDULE OF RATES'. AN APPOINTMENT IS SCHEDULED FOR WATER METER INSTALLATION, GRANTED ALL CONNECTION FEES HAVE BEEN SATISFIED.
ALL METERS ARE SUPPLIED BY THE AUTHORITY. (METERS 1 1/2 INCHES OR LARGER ARE INSTALLED BY THE CONTRACTOR BUT INSPECTED BY AUTHORITY PERSONNEL. METERS SMALLER THAN 1 1/2 INCHES WILL BE INSTALLED BY AUTHORITY PERSONNEL.)
CURB STOPS AND SEWER CLEAN-OUTS ARE NOT PERMITTED IN DRIVEWAYS OR SIDEWALKS AND MUST BE SET TO GRADE BEFORE THE METER CAN BE INSTALLED. A TUB AND/OR SINK MUST BE INSTALLED IN ORDER TO FLOW TEST THE METER. NEW CONSTRUCTION MUST HAVE HEAT.
NOTE: IF THE METER SPREAD OR OTHER REQUIREMENTS ARE NOT MET, AN ADDITIONAL FEE, IN ACCORDANCE WITH THE CURRENT 'SCHEDULE OF RATES' WILL BE APPLIED TO THE ACCOUNT AND MUST BE PAID IN FULL BEFORE A SECOND INSTALLATION IS ATTEMPTED.
ONCE THE AUTHORITY HAS DETERMINED THAT THE METER HAS BEEN SUCCESSFULLY INSTALLED AND TESTED, CUSTOMER SERVICE WILL ISSUE A LETTER OF COMPLIANCE FOR PRESENTATION TO THE TOWNSHIP.
N.T.S.
NOTE: LOCATION OF SERVICE CONNECTION & CLEANOUT SHALL BE DETERMINED IN THE FIELD TO COMPLY WITH REQUIREMENTS OF THE PROPERTY OWNER & M.U.A. CLEAN-OUT IS NOT PERMITTED IN DRIVEWAY OR SIDEWALK. SHOULD NO CURBING EXIST, THE AUTHORITY WILL DETERMINE WHETHER OR NOT A 2'x2'x6" CONCRETE COLLAR BE CONSTRUCTED.
N.T.S.
N.T
DETAIL A
STANDARD MANHOLE
N.T.S.
The original Bosch EV200 Series will work with all electric vehicles in North America, providing unparalleled value and reliability. The weather-resistant housing is suitable for indoor or outdoor installations.
With 16- and 30-amp options and a cable length up to 25 feet, there is a Bosch EV200 Series to perfectly match your charging needs. Charge at up to 7.2 kW for larger EV batteries, reducing overall charging time compared to the factory 110V cordset.
Bosch has engineered Bosch Level 2 EV Charger to meet or exceed SAE J1772, NEC 625 and NEMA 3R standards. Bosch EV200 Series has earned cUL and UL listing with integrated safety features that protect the driver and vehicle.
ITEM DESCRIPTION CATALOG NUMBERS AND SIZES
FOR 5/8" METER FOR 1" METER
A COIL PITSETTER METER PIT PFCBHH-188-18-60-FP-NL PFCBHHCR-488-18-60-FP-NL
B MIP INLET AND OUTLET 3/4" 1"
C COIL TUBING 3/4" 1"
D LOWER MOUNTING BRACKET (INCLUDED IN ITEM "A")
E MOUNTING PLATE (INCLUDED IN ITEM "A")
F ANGLE DUAL CHECK VALVE (INCLUDED IN ITEM "A")
G ANGLE BALL VALVE (INCLUDED IN ITEM "A")
H INSULATING DISK (4" THICK) CCID-18-4
J PIT COVER W/ERT BRACKET PPSC-18-L-P-BR
3. OWNER IS RESPONSIBLE FOR ALL FITTINGS REQUIRED TO CONNECT SERVICE LINES TO LOWER FITTINGS.
N.T.S
. ANY VALVE (WATER OR FORCE MAIN) INSTALLED OUTSIDE OF ASPHALT AREAS MUST BE CONSTRUCTED WITH A 2'x2'x6" CONCRETE COLLAR AROUND IT.
N.T.S.
| EV200 Series Specifications | 30A/18V cable | 30A/25V cable |
|---|---|---|
| Part No. | EL-61253-A | EL-61254-A |
| Amperage | 30 Amps | 30 Amps |
| Voltage | 208 VAC - 240 VAC | 208 VAC - 240 VAC |
| Cable Length | 18 ft | 25 ft |
| Weight | 14 lbs | 17 lbs |
| Dimensions | 16" x 14" x 5" | 16" x 14" x 5" |
| Input/Output Power | 7.2 kW | 7.2 kW |
| Enclosure | NEMA Type 3R, indoor/outdoor | NEMA Type 3R, indoor/outdoor |
ELECTRIC CAR CHARGER STATON DETAIL N.T.S.
N.T.S.