4”—6” STRIPPING DEPTH IS COMMON (BUT MAY VARY). STOCKPILES SHOULD BE SITUATED SO AS NOT TO OBSTRUCT DRAINAGE OR CAUSE OFFSITE ENVIRONMENTAL DAMAGE. STOCKPILES SHOULD BE VEGETATED IN ACCORDANCE WITH STANDARDS DESCRIBED HEREON. REFER TO TEMPORARY OR PERMANENT VEGETATIVE COVER FOR SOIL STABILIZATION.
DETAIL 14-4 SEDIMENT CONTROL BAG FOR DEWATERING Where a stabilized construction exit traverses between two buildings, it shall be stoned the entire length of the right-of-way. Mountable stone berms placed across the width of the exit may also be required at the transition point between paved and non-paved areas to trap sediments which are carried by stormwater flowing along the curbline.
NOT TO SCALE
Fence posts shall be spaced 8 feet center-to-center or closer. They shall extend at least 2 feet into the ground and extend at least 2 feet above ground (Fig. 23-2). Posts shall be constructed of hardwood with a minimum diameter thickness of 11/2 inches.
THE SOIL EROSION INSPECTOR MAY REQUIRE ADDITIONAL SOIL EROSION MEASURES TO BE INSTALLED, AS DIRECTED BY THE DISTRICT INSPECTOR, IN ACCORDANCE WITH THE STATE STANDARDS FOR SOIL EROSION AND SEDIMENT CONTROL IN NEW JERSEY
TEMPORARY OR PERMANENT VEGETATIVE COVER FOR SOIL STABILIZATION.
STOCKPILES NOT TO BE PLACED IN AREA WITH CONCENTRATED FLOW, WETLANDS, EXTREME SLOPE, OR WITHIN 100' OF NATURAL STREAM
TOPSOIL STOCKPILE DETAIL
NOT TO SCALE
SOIL EROSION & SEDIMENT CONTROL PLAN PROPOSED HOUSE OF WORSHIP 922 HYSON ROAD BLOCK 1204 LOT 34 TOWNSHIP OF JACKSON, OCEAN COUNTY, NEW JERSEY OWNER/APPLICANT: 922 HYSON LLC
Note: soil should be moist but not saturated. Do not test when soil is excessively dry or subject to freezing temperatures. Slow, steady downward pressure used to advance the probe. Probe must penetrate at least 6" with less than 300 psi reading on the gage.
Penetrometer may be re-inserted if/when an obstruction (rock, root, debris) is encountered. 6.0" min. visible mark on wire at depth
6.0" min. visible mark on shaft at depth