UNDERGROUND BASIN — SECTION VIEW NOT TO SCALE
UNDERGROUND BASIN — PLAN VIEW
NOT TO SCALE
LOAD BEARING CONCRETE COLLAR SHALL BE CONSTRUCTED IN TRAFFIC AREAS SUCH THAT THE LIVE LOAD IS TRANSMITTED TO THE SURROUNDING SOIL AND NOT DIRECTLY TO THE RISER.
CLEANOUT DETAIL
NOT TO SCALE
OUTLET CONTROL STRUCTURE 1
NOTE:
←→ = DIRECTION OF RUNOFF
SMALL SCALE SURFACE INFILTRATION BASIN
NOT TO SCALE
REV. - 7-22-2024 EXPANDED CIRCULATION DRIVE
CONSTRUCTION DETAILS
PROPOSED HOUSE OF WORSHIP
922 HYSON ROAD
BLOCK 1204 LOT 34
TOWNSHIP OF JACKSON, OCEAN COUNTY, NEW JERSEY
OWNED / APPLICANT. 922 HYSON LLC
OWNER/APPLICANT: 922 HYSON LLC
HALER CONSULTING PROFESSIONAL ENGINEERING SERVICES
HALER CONSULTING
PROFESSIONAL ENGINEERING SERVICES
PROJECT NO.
JACKSON, NEW JERSEY 08527
PH.(732) 351-2583 F.(732) 806-7439
OFFICE@HALERCONSULTING.COM
COA 24GA28321300
AS SHOWN
DATE
03-29-2024
ERIC HALPERT, PROFESSIONAL ENGINEER AND PLANNER
NJ PE LIC. NO. 55771 NJ PP LIC. NO. 6488
C801