PROPOSED HOUSE of WORSHIP
922 HYSON ROAD
JACKSON, NJ
JACKSON, NJ
LEWIS ELIEZER GARFINKEL, R.A.
ARCHITECT
N.J. REG. NO. 2919 AVENUE J
14521 BROOKLYN, NEW YORK 11210
TEL. 718-951-6551
MAIN BAIS MEDRASH (ASSEMBLY) - 2,085 SF / 15 NET = 139 OCCUPANTS
OTZER (ASSMEBLY) - 524 SF / 15 NET = 35 OCCUPANTS
RABBI'S STUDY (OFFICE) - 129 SF / 100 NET = 1 OCCUPANT
TOTAL FIRST FLOOR = 175 OCCUPANTS
CONSULTANTS:
SECOND FLOOR -
WOMEN'S SECTION (ASSEMBLY) - 1,196 SF / 15 NET = 80 OCCUPANTS
TOTAL SECOND FLOOR = 80 OCCUPANTS
BUILDING CODE DATA
CODE: NEW JERSEY BUILDING CODE 2021
USE GROUP: A-3
CONSTRUCTION TYPE: VB SPRINKLERED
BUILDING CLASS: 2
COMMUNITY HALL (ASSEMBLY) - 2,410 SF / 15 NET = 161 OCCUPANTS FOOD PREP AREA (KITCHEN) - 200 SF / 200 NET = 2 OCCUPANTS TOTAL SECOND FLOOR = 163 OCCUPANTS
TOTAL BUILDING = 243 OCCUPANTS
TYPE OF CONSTRUCTION: V-B (SPRINKLERED)
OCCUPANCY GROUP: A-3
ALLOWABLE AREA PER TABLE 506 = 18,000 SF PER STORY
ALLOWABLE HEIGHT PER TABLE 504 = 2 STORIES, 60' HEIGHT
FRONTAGE INCREASE PER SECTION 506.2: NEW BUILDING, THUS NOT APPLICABLE AUTOMATIC SPRINKLER INCREASE PER TABLE 506.2 = 18,000 SF ALLOWABLE PER STORY
PROPOSED BUILDING AREA FOR 'A-3' USE:
FIRST FLOOR = 90'-0" X 54'-0" = 4,860 SF -- COMPLIES
SECOND FLOOR = 90'-0" X 54'-0" = 4,860 SF -- COMPLIES
1 SITE PLAN
SCALE: NTS
REVISIONS: | NOTES:
PLOT DATE: 4/18/2024 9:25:12 AM
MECHANICAL PLANS BY OTHERS
FIRE ALARM PLANS BY OTHERS
SPRINKLER PLANS BY OTHERS
SPRINKLER ENGINEER/DESIGNER TO PROVIDE SPRINKLER HEADS
Additional Soffits, Chases, Shafts, Etc. and Coordination may be Req'd by MEP Engineer's Drawing. Contractor shall Coordinate with Owner
EGRESS WIDTH PER OCCUPANT SERVED (SECTION 1005)
STAIRWAYS WITH SPRINKLER - 0.2 INCHES PER OCCUPANT
175 OCCUPANTS = 35" MIN. REQ. - 36" PROVIDED
OTHER EGRESS COMPONENTS WITH SPRINKLER - 0.15" PER OCCUPANT
175 OCCUPANTS = 26.25" MIN. REQ. - 36" PROVIDED
STAIRWAYS WITH SPRINKLER - 0.2 INCHES PER OCCUPANT
80 OCCUPANTS = 16" MIN. REQ. - 36" PROVIDED
OTHER EGRESS COMPONENTS WITH SPRINKLER - 0.15" PER OCCUPANT
80 OCCUPANTS = 12" MIN. REQ. - 36" PROVIDED
STAIRWAYS WITH SPRINKLER - 0.2 INCHES PER OCCUPANT
163 OCCUPANTS = 32.6" MIN. REQ. - 36" PROVIDED
OTHER EGRESS COMPONENTS WITH SPRINKLER- 0.15" PER OCCUPANT
163 OCCUPANTS = 24.45" MIN. REQ. - 36" PROVIDED
NEW BUILDING
922 HYSON RD.
JACKSON, NJ
COVER SHEET
SEAL & SIGNATURE
DATE: 4/16/24
PROJECT No. 23-083
DRAWING BY: qmp
CHK BY: LG
DWG No.
C-001.00
DWG SCALE: AS NOTED
1 OF 8
<table><tr><td>DATE:</td><td>4/16/24</td></tr><tr><td>PROJECT No.</td><td>23-083</td></tr><tr><td>DRAWING BY:</td><td>qmp</td></tr><tr><td>CHK BY:</td><td>LG</td></tr><tr><td colspan="2">DWG No.</td></tr><tr><td colspan="2">C-001.00</td></tr><tr><td>DWG SCALE:</td><td>AS NOTED</td></tr><tr><td colspan="2">1 OF 8</td></tr></table>
(TABLE 1010.1.1) MIN. WIDTH FOR EGRESS DOOR 32" CLEAR - PROVIDED
MAXIMUM EXIT ACCESS TRAVEL DISTANCE(TABLE 1017.2) ASSEMBLY WITH SPRINKLER-250 FEET - PROVIDED