Summary for Subcatchment 15S: Study Area Roof (Imp)

Runoff = 0.79 cfs @ 12.19 hrs, Volume= 0.102 af, Depth=11.17" Routed to Link 16L : Study Area Basin A (Total)

Runoff by SCS TR-20 method, UH=Delmarva, Weighted-CN, Time Span= 0.00-72.00 hrs, dt= 0.05 hrs NOAA 24-hr D 100-Year-Projected Rainfall=11.41"

Area (ac) CN Description

0.110 98 Roofs, HSG A

0.110 98 100.00% Impervious Area

Tc (min) Length (feet) Slope (ft/ft) Velocity (ft/sec) Capacity (cfs)

0.8 207 0.0100 4.50 1.57

0.8 207 Total, Increased to minimum Tc = 10.0 min

Subcatchment 15S: Study Area Roof (Imp)

2026-02 Existing and Proposed NOAA 24-hr D 100-Year-Projected Rainfall=11.41"

Prepared by Dynamic Engineering Printed 2/10/2026

HydroCAD\circledR 10.20-8a s/n 08640\circledR 2025 HydroCAD Software Solutions LLC Page 124

Summary for Subcatchment 19S: Study Area Road Undetained (Perv)

Runoff = 0.17 cfs @ 12.21 hrs, Volume= 0.022 af, Depth= 2.87"

Routed to Link 18L : Study Area Road Undetained (Total)

Runoff by SCS TR-20 method, UH=Delmarva, Weighted-CN, Time Span= 0.00-72.00 hrs, dt= 0.05 hrs

NOAA 24-hr D 100-Year-Projected Rainfall=11.41"

Area (ac)CNDescription
0.09039>75% Grass cover, Good, HSG A
0.09039100.00% Pervious Area
Tc (min)Length (feet)Slope (ft/ft) Velocity (ft/sec) Capacity (cfs)
4.8580.0300 0.20
Sheet Flow, A-B
Grass: Short n= 0.150 P2= 4.04"

4.8 58 Total, Increased to minimum Tc = 10.0 min

Subcatchment 19S: Study Area Road Undetained (Perv)

Runoff