RGC-2 – Regional Growth Commercial – Per §244-96C(1) area, yard and building requirements shall be same as required in the PVC-2 Pinelands Village Commercial Zone Per §244-94C(1).
| ITEM | REQUIRED | PROPOSED | STATUS |
|---|---|---|---|
| Minimum Lot Area | 20,000 sf | 49,270 sf | Conforms |
| Minimum Lot Width | 100 ft | 188.8 ft | Conforms |
| Minimum Front Yard Setback | 60 ft | 78.5 ft | Conforms |
| Minimum Side Yard Setback (Each) | 10 ft | 44.5 ft | Conforms |
| Minimum Combined Side Yard Setback | 30 ft | 99.6 ft | Conforms |
| Minimum Rear Yard Setback | 30 ft | 96.1 ft | Conforms |
| Maximum Building Height | 35 ft | 36 ft (V)(1)\nTo Roof | Variance |
| Maximum Building Height | 35 ft | 39 ft To Parapet | Conforms |
| Maximum Building Height | 35 ft | 50 ft (TBD)(2)\nTo Bulkhead | TBD |
| Parking Area Setbacks | |||
| From ROW | 20 ft | 20.1 ft | Conforms |
| From Residential Use | 20 ft | 10.2 ft (V)(3) | Variance |
| From Nonresidential Use | 10 ft | 10 ft | Conforms |
| Minimum Required Parking Spaces | |||
| Office (Professional/Business) – 14,979 gsf 1 for each 200 sf of gross floor area | 14,979 gsf 1 space/200 sf 75 spaces | 63 spaces + 7 EV ready credited spaces = 70 spaces (V)(4) | Variance |
| Handicapped Parking Spaces | 3 Accessible spaces | 3 Accessible spaces | Conforms |
| Wall Signage | |||
| Maximum Number of Signs | 1 | 2 (V)(5) | Variance |
| Maximum Sign Area | not to exceed 15% of the principal façade area or 80 sf, whichever is smaller | 1 – 30 sf (West Elevation) 1 - 30 sf (North Elevation) | Conforms |