Page 3

single-family dwelling use.

  1. Per §244-87A(2) detached single-family dwellings are a permitted use.
  2. Area & Bulk Standards for the PV - Pinelands Village Zone - 244-87C:

1. Per §244-87C(2) area & bulk standards for any proposed residential use served by an alternate design pilot program treatment system, in accordance with § 244-79G(4)(f).

ITEMREQUIRED §244-87C(2)PROPOSED LOT APROPOSED LOT BSTATUS
Minimum Lot Area1 acre1.025 acres1.026 acresConforms
Minimum Lot Width125 ft± 210 ft± 35 ft (V)(1)Variance
Minimum Lot Depth250 ft209 ft (V)(2)TBD(3)Variance
Principal Building
Minimum Front Yard Setback60 ft83.8 ftN/AConforms
Minimum Side Yard Setback10 ft35.6 ftN/AConforms
Minimum Combined Side Yard Setback30 ft111.3 ftN/AConforms
Minimum Rear Yard Setback50 ft133 ftN/AConforms
Maximum Building Height35 ft<35 ftN/AConforms
Accessory Building
Minimum Front Yard SetbackNot PermittedN/AN/AN/A
Minimum Side Yard Setback10 ftN/AN/AN/A
Minimum Rear Yard Setback10 ftN/AN/AN/A

V-Variance N/A - Not Applicable TBD - To Be Determined

Notes:

  1. The definition of Lot Width is the shortest horizontal distance between the side lot lines measured through the midpoint of a line parallel to the front lot line located at the minimum building setback line required in the zoning district where the lot is located.
  2. The definition of Lot Depth is the shortest distance between the front lot line and a line drawn parallel thereto through the midpoint of the rear lot line.
  3. As indicated on the Pinelands Commission Certificate of Filing “Prior to Commission issuance of a letter advising that any final municipal subdivision approval may take effect, documentation must be submitted to the Pinelands Commission that the existing standard septic system located on proposed Lot A depicted on the above referenced plan has been converted to one of the alternate design septic systems on the enclosed list.”
  4. Per §244-87C(2)(b) the minimum lot width if served by an alternate design pilot program treatment system is 125 ft, whereas New Lot B is approximately 35 ft. A variance may be required.
  5. Per §244-87C(2)(c) the minimum lot depth if served by an alternate design pilot program