single-family dwelling use.
- Per §244-87A(2) detached single-family dwellings are a permitted use.
- B.Area & Bulk Standards for the PV - Pinelands Village Zone - 244-87C:
1. Per §244-87C(2) area & bulk standards for any proposed residential use served by an alternate design pilot program treatment system, in accordance with § 244-79G(4)(f).
| ITEM | REQUIRED §244-87C(2) | PROPOSED LOT A | PROPOSED LOT B | STATUS |
|---|
| Minimum Lot Area | 1 acre | 1.025 acres | 1.026 acres | Conforms |
|---|
| Minimum Lot Width | 125 ft | ± 210 ft | ± 35 ft (V)(1) | Variance |
|---|
| Minimum Lot Depth | 250 ft | 209 ft (V)(2) | TBD(3) | Variance |
|---|
| Principal Building | | | | |
|---|
| Minimum Front Yard Setback | 60 ft | 83.8 ft | N/A | Conforms |
|---|
| Minimum Side Yard Setback | 10 ft | 35.6 ft | N/A | Conforms |
|---|
| Minimum Combined Side Yard Setback | 30 ft | 111.3 ft | N/A | Conforms |
|---|
| Minimum Rear Yard Setback | 50 ft | 133 ft | N/A | Conforms |
|---|
| Maximum Building Height | 35 ft | <35 ft | N/A | Conforms |
|---|
| Accessory Building | | | | |
|---|
| Minimum Front Yard Setback | Not Permitted | N/A | N/A | N/A |
|---|
| Minimum Side Yard Setback | 10 ft | N/A | N/A | N/A |
|---|
| Minimum Rear Yard Setback | 10 ft | N/A | N/A | N/A |
|---|
V-Variance N/A - Not Applicable TBD - To Be Determined
Notes:
- The definition of Lot Width is the shortest horizontal distance between the side lot lines measured through the midpoint of a line parallel to the front lot line located at the minimum building setback line required in the zoning district where the lot is located.
- The definition of Lot Depth is the shortest distance between the front lot line and a line drawn parallel thereto through the midpoint of the rear lot line.
- As indicated on the Pinelands Commission Certificate of Filing “Prior to Commission issuance of a letter advising that any final municipal subdivision approval may take effect, documentation must be submitted to the Pinelands Commission that the existing standard septic system located on proposed Lot A depicted on the above referenced plan has been converted to one of the alternate design septic systems on the enclosed list.”
- Per §244-87C(2)(b) the minimum lot width if served by an alternate design pilot program treatment system is 125 ft, whereas New Lot B is approximately 35 ft. A variance may be required.