| REQUIRED | PROPOSED | |||||||
| AREA | MIN | AVG | MIN | MAX | MAX/MIN | AVG/MIN | COMPLIANCE | |
|---|---|---|---|---|---|---|---|---|
| PARKING LOT, ADJACENT WALKWAYS, AND ACCESS DRIVES | 0.5 FC | 1.8 FC | 0.5 FC | 4.4 FC | 8.8:1 | 3.6:1 | COMPLIES | |
| TRUCK LOADING ZONE | 0.5 FC | 1.0 FC | 0.1 FC | 2.2 FC | 22.0:1 | 10.0:1 | DESIGN WAIVER | |
LUMINAIRE SCHEDULE
| LABEL | SYMBOL | QTY | MANUFACTURER | MODEL NO. | TEMPERATURE | LUMENS | WATTS | ARRANGEMENT | THROW | LLF | HEIGHT | FILE NAME |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A | ➡ | 2 | KIM LIGHTING | WDS-D-24L-30-3K7-4F | 3,000K | 3,343 | 28.8 | AREA (WALL) | TYPE 4F | 1.0 | 15' | WDS-D-24L-30-3K7-4F.IES |
| B | ⬆ | 10 | KIM LIGHTING | WDS-D-24L-30-3K7-4W | 3,000K | 3,267 | 29.0 | AREA (WALL) | TYPE 4W | 1.0 | 15' | WDS-D-24L-30-3K7-4W.IES |
| C | ⬆ | 1 | BEACON LIGHTING | VP-1-160L-100-3K7-5QW | 3,000K | 12,500 | 184.0 | AREA (TWIN) | TYPE 5QW | 1.0 | 25' | VP-1-160L-100-3K7-5QW.IES |
| D | ✉ | 1 | BEACON LIGHTING | VP-1-160L-100-3K7-4F | 3,000K | 12,500 | 184.0 | AREA (TWIN) | TYPE 4F | 1.0 | 25' | VP-1-160L-100-3K7-4F.IES |
| E | ❄ | 2 | BEACON LIGHTING | VP-1-160L-100-3K7-4F-HSS-90-B | 3,000K | 12,500 | 92.0 | AREA (POLE) | TYPE 4F HS | 1.0 | 25' | VP-1-160L-100-3K7-4F-HSS-90-B.IES |
| F | ❄ | 2 | BEACON LIGHTING | VP-1-160L-100-3K7-4W-BC | 3,000K | 12,500 | 97.2 | AREA (POLE) | TYPE 4W BC | 1.0 | 25' | VP-1-160L-100-3K7-4W-BC.IES |
| LIGHTING COMPLIANCE CHART | ||
| SECTION | REQUIREMENTS | COMPLIANCE |
|---|---|---|
| 244-160 L.(1) PERFORMANCE STANDARDS | THE ILLUMINATION PROVIDED BY ARTIFICIAL LIGHTING ON THE PROPERTY SHALL NOT EXCEED 0.5 FOOTCANDLE BEYOND ANY PROPERTY LINE. | COMPLIES |
ALL PARKING AREAS FOR 10 OR MORE VEHICLES SHALL HAVE ARTIFICIAL LIGHTING THAT WILL PROVIDE A MINIMUM LIGHTING LEVEL OF 0.5 HORIZONTAL FOOTCANDLE THROUGHOUT THE PARKING AREA AND ACCESS DRIVES. FOR MULTIFAMILY USES, SUCH LIGHTS SHALL BE OPERATED FROM DUSK TO DAWN AND FOR ALL OTHER USES WHEN THE SITE OR STRUCTURE IS OCCUPIED. FREESTANDING LIGHT POLES SHALL BE NO HIGHER THAN THE HEIGHT OF THE HIGHEST PRINCIPAL BUILDING OR 30 FEET, WHICHEVER IS LESS. SHIELDING SHALL BE REQUIRED WHERE NECESSARY TO PREVENT LIGHT TRESPASS GLARE UPON ADJACENT PROPERTIES OR STREETS.
AREA LIGHTS TO BE CONTROLLED VIA A PHOTOCELL TIMER TO TURN ON AT DUSK AND OFF AT DAWN
N ⊕
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINA AND UNPUBLISHED WORK OF THE ENGINEER AND MAY NOT BE DUPLICATED, USED OR
DISCLOSED WITHOUT WRITTEN CONSENT OF THE ENGINEER.
PROJECT: PRELIMINARY & FINAL MAJOR SITE PLAN FOR BLOCK 22401, LOT 7-12 LOCATION: JACKSON TOWNSHIP OCEAN COUNTY NEW JERSEY
DRAWING TITLE: LIGHTING PLAN
PROJECT NO. 23089 DATE 01/22/25 DRAWN BY HH CHECKED BY YP
Digitally signed by Yosef Portnoy Date: 2026.01.19 11:34:43-05'00' YOSEF PORTNOY SCALE AS NOTED SHEET NO. 10 OF 24
LICENSED PROFESSIONAL ENGINEER NJ LICENSE NO: GE53593