Site Plan Sheet 10 of 23 details the overall site lighting which is proposed. Based on lighting levels indicated proposed site lighting is acceptable. However, timing associated with activating/deactivating should be specified. A light pole and fixture detail should also be provided.
Site Plan Drawing, Sheet 7 of 23 indicates the overall site landscaping which is proposed. The applicant should be prepared to discuss the following issues:
Compliance with Ordinance Section 244-197i.3.9.b requiring tree and shrub plantings within all safety island areas. Unless otherwise directed by the Board, additional shrub plantings should be added across the entire Whitesville Road frontage.
Extent and adequacy of buffer and screen plantings to all adjacent residential uses. Based on the total commercial floor area which is proposed, a 100 FT wide screen buffering is required adjacent to Whitesville Road.
Extent and nature of all stormwater management basin screen plantings.
Irrigation proposals.
Architectural Considerations – Although architectural floor plan and elevation drawings have been provided, specific architectural treatments including color schemes, surfacing materials, etc., cannot be specifically established. The applicant should be prepared to review proposed architectural treatments as well as address any specific questions the Board may have. Colored renderings should be available for Board review.
Environmental Impact Statement (244-30): Environmental Impact Statement Required; Not Provided.
Concrete Sidewalk (244-203): Concrete Sidewalk Required along all existing road frontages; Not Provided.