Jackson Township Planning Board Our file No. 1512-P-620
Page 5
Warehouse Use:
Per §244-97A(5) the warehousing or storage of goods and products, provided that no goods are sold from the premises, and provided further that all items to be stored are within an enclosed building.
The Applicant shall provide testimony to discuss the warehouse use in detail. The testimony shall include the proposed area for the storage of small machines.
Storage Sheds:
Per §244-57B(6) accessory uses customarily associated with the industrial, research or office uses permitted in § 244-97A above.
The Applicant shall provide testimony to discuss the proposed storage sheds in detail to determine if they are a permitted accessory use.
B. Area & Bulk Standards:
PM-1 Pinelands Manufacturing Zone - §244-97D
ITEMREQUIREDPROPOSEDSTATUS
Minimum Lot Area2 acres6.1 acresConforms
Minimum Lot Frontage200 ft214.78 ftConforms
Minimum Front Yard Setback Major Road100 ft113.34 ftConforms
Minimum Front Yard Setback Other Roads60 ft113.34 ftConforms
Minimum Rear Yard Setback50 ft211.65 ftConforms
Minimum Side Yard Setback25 ft30 ftConforms
Minimum Side Yard Setback (Combined)60 ft>60 ftConforms
Maximum Building Height50 ft45 ftConforms
Maximum Lot Coverage50%49.71%Conforms
Parking Area Setbacks
From ROW20 ft41.68 ftConforms
From Residential20 ftN/AN/A
From Nonresidential10 ft10 ftConforms
Min. Required Parking Spaces
Office Use (15,000 sf) 1 parking space/200 sf of gsf14,334 sf/200 sf = 72 spaces89 spaces + 4 EV credited spaces