## SEPTIC SYSTEM CALCULATIONS:
DESIGN: EDUCATIONAL USE
A-5
200 STUDENTS/TEACHERS
10 GPD PER STUDENT/TEACHER
200 X 10 GPD = 2,000 GPD TOTAL
2,000 GPD X 1.33 = 2,660 S.F DISPOSAL AREA
2,660 S.F. X 1.5 (EJECTOR PUMP) = 3,990 S.F. DISPOSAL AREA REQUIRED
PRESSURE DOSING SYSTEM
70' X 57' = 3,990 S.F. DISPOSAL AREA PROVIDED
SEPTIC TANK: 10 GPD X 200 STUDENTS/TEACHERS = 2,000 GPD
2,000 GPD X 0.75 + 1,125 GAL. = 2,625 GAL.
2,625 GAL. X 1.5 (EJECTOR PUMP) = 3,937.5 GAL. SEPTIC TANK REQUIRED
2 2,000 GAL. SEPTIC TANKS PROVIDED
## CONSTRUCTION NOTES
CONSTRUCTION TO BE IN ACCORDANCE WITH APPROVED SITE PLAN PER RESOLUTION NO. 2023-17. WITH CONDITIONAL APPROVAL ON MAY 15, 2023.
IMPROVEMENTS TO FARMINGDALE ROAD AND PFISTER ROAD TO BE CONSTRUCTED WITH APPROVED SITE PLAN IMPROVEMENTS
JOR SUBDIVISION AND AMENDED PRELIMINARY AND FINAL MAJOR SITE PLAN
UTILITY PLAN
1020 FARMINGDALE ROAD
BLOCK 1102 LOT 24.02 & BLOCK 1101 LOT 34
JACKSON TOWNSHIP, OCEAN COUNTY, NEW JERSEY
CALL BEFORE YOU DIG
1-800-272-1000 It's THE LAW
SEY ONE CALL Dig Safely.
GRAPHIC SCALE
12–18–2025 REVISIONS PER PFISTER ROAD REALIGNMENT
5–27–2025 REVISED PER OCPB LETTER DATED 07–17–2024
5–2–2024 REVISED PER OL&A LETTER DATED 03–08–2024
5–2–2024 REVISED PER OCPB LETTER DATED 03–20–2024
1–31–2024 REVISED PER OCPB LETTER DATED 10–4–2023
8–07–2023 REVISED PER CME LETTER DATED 5–2–2023
8–07–2023 REVISED PER RVE LETTER DATED 5–10–2023 & OL&A LETTER DATED 5–11–2023
4–27–2023 REVISED PER JACKSON TOWNSHIP PLANNING BOARD REVIEW LETTERS DATED 03–22–23
3–14–2023 REVISED PER JACKSON TOWNSHIP PLANNING BOARD REVIEW LETTERS
1–23–2023 REVISED PER OCSCD LETTER DATED 1–10–2023
12–29–2022 REV. PER JACKSON TOWNSHIP POLICE DEPARTMENT LETTER DATED 10–13–22
11–24–2022 REVISED PER OCSCD LETTER DATED 11–02–2022
DATE DESCRIPTION
NEWLINES
EW JERSEY CERTIFICATE OF AUTHORIZATION #24GA28264200
315 Monmouth Avenue
No.
NO. 40279
N.J. PROFESSIONAL ENGINEER NO. 24GE040279
N.J. PROFESSIONAL PLANNER NO. 33LI005650
TIMOTHY P. LURIE, P.E., P.P.
Suite 205
Lakewood, New Jersey 0870
Phone (732) 994-4900
Fax (732) 358-0423
[Unabel]
PROJECT NO. 22001
MH
SCALE $1$" = 40'
N.J. PROFESSIONAL ENGINEER NO. 24GE040279 DATE 05-11-2023