| REQUIRED R-1 | REQUIRED R-3 | PROPOSED NEW LOT 20.01 | STATUS | |
|---|---|---|---|---|
| Max. Building Height | 25 ft | 25 ft | <25 ft | Conforms |
| Pool | ||||
| Front Yard Setback | Not Permitted | Not Permitted | Not in Front Yard | Conforms |
| Rear Yard Setback | 15 ft | 25 ft | >25 ft | Conforms |
| Side Yard Setback | 20 ft | 50 ft | 29.2 ft (EV)(6) | Pre-Existing Non-Conforming Condition |
Area & Bulk Standards for the R-20 – Residential Zone Per §244-48D are as follows for New Lot 31.01. The Area & Bulk Standards for the R-1 – Residential Zone Per §244-47D are also included since the proposed improvements are located within both zones and the R-1 Zone is more restrictive:
| REQUIRED R-20 | REQUIRED R-1 | PROPOSED NEW LOT 31.01 | STATUS | |
|---|---|---|---|---|
| Lot Requirements | ||||
| Min. Lot Area | 20,000 sf | 43,560 sf | 45,168.34 sf | Conforms |
| Min. Lot Width | 100 ft | 150 ft | 100 ft (V)7 | Variance |
| Min. Lot Frontage | 100 ft | 75 ft | 100 ft | Conforms |
| Min. Lot Depth | 200 ft | 200 ft | >200 ft | Conforms |
| Principal Structure | ||||
| Min. Front Yard Setback | 30 ft | 40 ft | 42.8 ft | Conforms |
| Min. Rear Yard Setback | 35 ft | 50 ft | >50 ft | Conforms |
| Min. Side Yard Setback | 15 ft | 20 ft | 24.8 ft | Conforms |
| Max. Building Height | 35 ft | 35 ft | <35 ft | Conforms |
| Max. Building Coverage | 30% | 15% | 4.04% | Conforms |
| Max. Lot Coverage | 70% | 50% | 13.04% | Conforms |
| Accessory Structure | ||||
| Shed | ||||
| Front Yard Setback | Not Permitted | Not Permitted | Not in Front Yard | Conforms |
| Rear Yard Setback | 15 ft | 15 ft | >15 ft | Conforms |
| Side Yard Setback | 15 ft | 15 ft | 1.7 ft (EV)8 | Pre-Existing Non-Conforming Condition |
| Max. Building Height | 15 ft | 15 ft | <15 ft | Conforms |
| Pool | ||||
| Rear Yard Setback | 15 ft | 15 ft | >15 ft | Conforms |