Inflow Area = 0.460 ac, 58.70% Impervious, Inflow Depth > 2.83" for 10 YEAR event
Inflow = 1.48 cfs @ 12.08 hrs, Volume= 0.108 af
Outflow = 0.10 cfs @ 13.45 hrs, Volume= 0.088 af, Atten= 93%, Lag= 82.1 min
Discarded = 0.10 cfs @ 13.45 hrs, Volume= 0.088 af
Primary = 0.00 cfs @ 5.00 hrs, Volume= 0.000 af
Routed to Reach 10: COMPOSITE
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 108.89' @ 13.45 hrs Surf.Area= 0.064 ac Storage= 0.047 af
Plug-Flow detention time= 160.2 min calculated for 0.088 af (81% of inflow)
Center-of-Mass det. time= 102.6 min (841.8 - 739.2)
| Volume | Invert | Avail.Storage | Storage Description |
|---|
| #1A | 107.50' | 0.048 af | 41.95"W x 66.33"L x 3.00"H Field A |
| 0.192 af Overall - 0.072 af Embedded = 0.120 af x 40.0% Voids |
| #2A | 107.83' | 0.057 af | ADS N-12 24" x 36 Inside #1
Inside= 23.8"W x 23.8"H => 3.10 sf x 20.00"L = 62.0 cf
Outside= 28.0"W x 28.0"H => 3.92 sf x 20.00"L = 78.4 cf
36 Chambers in 12 Rows
40.28' Header x 3.10 sf x 2 = 249.8 cf Inside |
| | 0.105 af | Total Available Storage |
| Device | Routing | Invert | Outlet Devices |
|---|
| #1 | Discarded | 107.50' | 1.000 in/hr Exfiltration over Surface area
Conductivity to Groundwater Elevation = 105.00' |
| #2 | Primary | 109.00' | 8.0" W x 4.0" H Vert. Orifice/Grate C= 0.600
Limited to weir flow at low heads |
| Discarded OutFlow | Max=0.10 cfs @ 13.45 hrs HW=108.89' (Free Discharge) |
| 1=Exfiltration ( Controls 0.10 cfs) |
| Primary OutFlow | Max=0.00 cfs @ 5.00 hrs HW=107.50' (Free Discharge) |
| 2=Orifice/Grate ( Controls 0.00 cfs) |