Page 5

ITEMREQUIREDPROVIDEDSTATUS
From Residential20 ft7.23 ft (V)(11)Variance
From Non-residential10 ftN/AN/A
Parking Requirement
Existing Building
Office (2,160 sf) 1 space/200 sf of gfa2,160 sf/200 sf = 11 parking spaces42 parking spaces + 2 EV credited spaces
Warehouse Building (4,000 sf) 1 space/1,500 sf of gfa + 1 for each vehicle used in connection with the business4,000 sf/1,500 sf = 3 parking spaces + 2 vehicles used in connection with the business = 5 parking spaces
Proposed Building
Office (1,000 sf) 1 space/200 sf of gfa1,000 sf/200 sf = 5 parking spaces
Warehouse Building (19,000 sf) 1 space/1,500 sf of gfa + 1 for each vehicle used in connection with the business19,000 sf/1,500 sf = 13 parking spaces + 5 vehicles used in connection with the business = 18 parking spaces
Total Parking Spaces Required39 spaces44 spacesConforms
Accessible Parking2 spaces2 spacesConforms
EV Ready Spaces 50 or fewer spaces requires a minimum of 1 EV Ready spaces (An EV Ready space shall count as no less than 2 parking spaces for the purposes of complying with a minimum parking space requirement provided it does not reduce more than 10% of otherwise required parking spaces.)1 space2 spacesConforms
Signage
Ground Sign - §244-207B(6)
Maximum Number of Signs21Conforms
Maximum Sign Area30 sf30 sfConforms
Maximum Sign Height6 ft6 ftConforms
Minimum Sign Setback from R.O.W.25 ft5 ft (V)(12)Variance