- Scale 1" = 200' and include bar scale.
- Storm drain improvements (existing and those to be constructed).
- Arrows indicating direction of surface flow in streets.
- Detention/retention or retarding basin location.
- Drywell locations.
- c.Benchmark - number, quad, description, date (year of adjustment), and elevation to three decimal places.
- d.Engineering firm name, address, telephone number, date of plan preparation, signature, stamp, R.C.E. number and date of expiration.
- e.Title block containing tract number and which phase of tentative tract number, if applicable; City-assigned "ST" number.
- f.Developer's name, address and telephone number.
- g.Signature block for Plan Check Engineer and a Recommended By block.
- h.Approval block for City Engineer's signature and date, and for other agencies when necessary.
- i.Revision block with revision number, date, initials of design engineer, description of plan change, index of sheets affected by the revision, and spaces for City approval and date.
- j.Applicable general notes.
- k.Typical sections showing:
- Each geometric street variation with limits, if applicable. (See STD No. M-8.3)
IV - 7