1. Scale 1" = 200' and include bar scale.
  2. Storm drain improvements (existing and those to be constructed).
  3. Arrows indicating direction of surface flow in streets.
  4. Detention/retention or retarding basin location.
  5. Drywell locations.
  6. Benchmark - number, quad, description, date (year of adjustment), and elevation to three decimal places.
  7. Engineering firm name, address, telephone number, date of plan preparation, signature, stamp, R.C.E. number and date of expiration.
  8. Title block containing tract number and which phase of tentative tract number, if applicable; City-assigned "ST" number.
  9. Developer's name, address and telephone number.
  10. Signature block for Plan Check Engineer and a Recommended By block.
  11. Approval block for City Engineer's signature and date, and for other agencies when necessary.
  12. Revision block with revision number, date, initials of design engineer, description of plan change, index of sheets affected by the revision, and spaces for City approval and date.
  13. Applicable general notes.
  14. Typical sections showing:
  15. Each geometric street variation with limits, if applicable. (See STD No. M-8.3)

IV - 7