*Requires special attention by checker.
[ ] 24" x 36" SHEET SIZE
[ ] BENCHMARK - County of Los Angeles, Palmdale Quad, elevation, location, benchmark number, description, date of adjustment. Temporary B.M. shall be set at 1000' grids to be utilized during grade checking.
[ ] TITLE BLOCKS - tract number and Palmdale number (bottom right and right margin), sheet number, phase, rough or final, City Engineer "approved by" "checked by", "recommended by", "Planning Department compliance" signature blocks ; name, address and phone for owner, developer, design engineer, soils engineer, geologist, revision block, list of items on sheet.
[ ] KEY MAP - scale 1" = 200', north arrow up, flow arrows, street names, street widths, dry well locations, lot lines and numbers, retention/detention basin location, key to sheet numbers, adjoining tract numbers, City Limits.
[ ] VICINITY MAP - Highway names, City Limits, north arrow up.
[ ] Engineers seal, expiration date, signature, date signed.
[ ] Legend and Symbols.
[ ] Job Address (where applicable).
[] * Offsite grading for drainage and slopes - need Drainage Acceptance Letter and/or Cut/Fill Acceptance Letter or easement recorded. (examples on II-21 & II-22)
[ ] General Notes (Reference pages II-7 thru II-11).
[ ] Private Engineer's Notice to Contractor.
Ⅱ-16