D. GRADING DESIGN CRITERIA
Grading shall conform to Chapter 70 of the City of Palmdale Building Code and the following criteria. In case of a discrepancy, the following criteria shall govern.
- I.Drainage
- a.Minimum Gradients for residential sites:
- Dirt, grass, etc. 1.0%
- Fine graded residential lot - dirt 2.0% sheet flow away from building pad for minimum of 3', pad shall be at least 0.3' above high point of swale.
- b.Minimum gradients for flat land industrial sites:
- Earth at rough grade stage 0.5%
- Earth fine grade 1.0%
- Asphalt Pavement (sheet flow) 1.0%
- Concrete Pavement (sheet flow) 1.0%
- Concrete drain in earth area 0.5%
- Concrete gutter in paved area 0.4%
- Maximum gradient for sheet flow 20.0%
- c.Design for water to flow to nearest practical street, storm drain or natural watercourse. Cross lot drainage is to be avoided.
- d.Show design and location of all drainage devices.
- e.Drainage shall not sheet flow over the top of any slopes steeper than 5:1.
- f.For residential lots, swales shall be 3 feet minimum from building pad.
- g.Common side yard swales are not acceptable.
Π-12