GROOVING DETAIL

LIP DETAIL

GENERAL NOTES:

  1. RAMPS SHALL HAVE A 12" BORDER ALONG PLATFORM. SEE GROOVING DETAIL FOR SPACING. THE SURFACE OF THE RAMP SHALL HAVE A TRANSVERSE BROOMED SURFACE TEXTURE ROUGHER THAN THE SURROUNDING SIDEWALK.
  2. RAMPS SHALL BE CONSTRUCTED OF CLASS 520-C-2500 PORTLAND CEMENT CONCRETE, FOUR (4) INCHES THICK.
  3. MINIMUM WALKWAY WIDTH = 36"

NOT TO SCALE

CITY OF PALMDALE DEPARTMENT OF PUBLIC WORKS

CURB RAMP-DETAIL SHEET STANDARD PLAN

APPROVED C-7

C:D ENGINEER 9-14-95

DATE