GROOVING DETAIL
LIP DETAIL
RAMPS SHALL HAVE A 12" BORDER ALONG PLATFORM. SEE GROOVING DETAIL FOR SPACING. THE SURFACE OF THE RAMP SHALL HAVE A TRANSVERSE BROOMED SURFACE TEXTURE ROUGHER THAN THE SURROUNDING SIDEWALK.
RAMPS SHALL BE CONSTRUCTED OF CLASS 520-C-2500 PORTLAND CEMENT CONCRETE, FOUR (4) INCHES THICK.
MINIMUM WALKWAY WIDTH = 36"
NOT TO SCALE
CITY OF PALMDALE DEPARTMENT OF PUBLIC WORKS
CURB RAMP-DETAIL SHEET STANDARD PLAN
APPROVED C-7
C:D ENGINEER 9-14-95
DATE