• Percolation report - 1 copy
  • Dry well calculations - 1 copy
  • Subsequent submittal to the City's Geologist shall be as required.
  • Prior to approval of grading plan:
  • Right of entry for any grading on adjacent properties. Permission to be in letter form signed by adjacent property owner and notarized. A form is available at the City Engineer's Office. This is required even if the owner of the impacted property is the developer of the subject project.
  • Drainage acceptance letter or easement from the owners of all affected properties. This is required even if the owner of the impacted property is the developer of the subject project.
  • Clearance from the City's Geologist.
  • Approval for compliance by the Planning Department

C. PLAN PREPARATION

  1. The plan size shall be 24" x 36", ink on 3 mil mylar and minimum scale 1" = 40'. Margins shall be 1.5" on the left edge and 1" on the other three sides. Deviations from sizing criteria must be approved by the Engineering Division.
  2. The first sheet shall be a title sheet and include:
  3. Location map showing the following:
  4. Project location
  5. Major cross streets
  6. City Limit lines if near the project
  7. North arrow
  8. Scale
  9. Index map showing the following:
  10. Street configuration within the project
  11. Lot configuration and numbers (include entire tentative tract or development)

Ⅱ-3