| Basin | Subsurface Infiltration Basin Lot 10 |
|---|
| Volume (cf) | | 1722 |
|---|
| Infiltration Area (sf) | | 348.48 |
|---|
| Recharge Rate (in/hr) | | 10 |
|---|
| Duration of infiltration period, t (hr) = | Volume of runoff to be infiltrated (cf) x 12 in/ft
Infiltration area (sf) x Recharge rate (in/hr) |
|---|
| Duration of Infiltration Period | | 5.93 |
|---|
| Basin | Subsurface Infiltration Basin Lot 3 |
|---|
| Volume (cf) | | 1722 |
|---|
| Infiltration Area (sf) | | 479.16 |
|---|
| Recharge Rate (in/hr) | | 4.05 |
|---|
| Duration of infiltration period, t (hr) = | Volume of runoff to be infiltrated (cf) x 12 in/ft
Infiltration area (sf) x Recharge rate (in/hr) |
|---|
| Duration of Infiltration Period | | 10.65 |
|---|
| Basin | Subsurface Infiltration Basin Lot 4 |
|---|
| Volume (cf) | | 1722 |
|---|
| Infiltration Area (sf) | | 479.16 |
|---|
| Recharge Rate (in/hr) | | 4.05 |
|---|
 |
Duration of Infiltration Period
10.65