Page 6

C. Area & Bulk Standards:

NC - Neighborhood Commercial - §244-56D

ITEMREQUIREDPROPOSEDSTATUS
Minimum Lot Area20,000 sf84,000 sfConforms
Minimum Lot Width125 ft300 ftConforms
Minimum Lot Frontage125 ft300 ftConforms
Minimum Lot Depth150 ft280 ftConforms
Minimum Front Yard Setback60 ft94.66 ftConforms
Minimum Side Yard Setback (Each)20 ft98.75 ftConforms
Minimum Side Yard Setback (Total)50 ft>50 ftConforms
Minimum Rear Yard Setback30 ft76.85 ftConforms
Maximum Building Height(1)35 ft35.47 ft (V)(2)Variance
Maximum Building Coverage25%13.1%Conforms
Maximum Impervious Coverage60%59.87%(3)Conforms
Parking Area Setbacks
From ROW20 ft43 ftConforms
From Residential Use20 ft25.16 ftConforms
From Nonresidential Use10 ftN/AN/A
Minimum Required Parking Spaces
Daycare – 32,955 gsf 1 for each 500 sf of gross floor area32,955 gsf 1 space/500 sf 66 spaces86 spaces + 6 EV ready credited spaces = 92 spacesConforms
Handicapped Parking Spaces (Based on 86 parking spaces)4 Accessible spaces4 Accessible spacesConforms
EV Parking Spaces 76 – 100 spaces requires a minimum of 3 EV Ready spaces (An EV Ready space shall count as no less than 2 parking spaces for the purposes of complying with a minimum parking space requirement provided it does not reduce more than 10% of otherwise required parking spaces.)3 EV Ready spaces6 EV Ready spacesConforms
  • V – Variance N/A – Not Applicable
  • The definition of “Building Height” per §244-6 is the vertical distance measured from the average elevation of the finished grade at all corners of the building to the highest point of the roof for flat roofs; to the mean height level of the distance measured between the eaves and ridge for gable