surface of the products pasteurized in vats, to make certain that the temperature of the foam and/or air above the products pasteurized also received the required minimum temperature treatment.
(2) Recording thermometers.
- HTST recording thermometers that are accurate within 1circ F., plus or minus, for the applicable temperature range, shall be used on each heat treating, pasteurizing, or sterilizing unit to record the heating process.
- (ii)Additional use of recording thermometers accurate within 2circ F., plus or minus, may be required where a record of temperature or time of cooling and holding is of significant importance.
- (i)Surface coolers. Surface coolers shall be equipped with hinged or removable covers for the protection of the product. The edges of the fins shall be so designed as to divert condensate on nonproduct contact surfaces away from product contact surfaces. All gaskets or swivel connections shall be leak proof.
- (j)Plate-type heat exchangers. Plate-type heat exchangers shall meet the 3-A Sanitary Standards for Construction and Installation. All gaskets shall be tight and kept in good operating order. Plates shall be opened for inspection by the operator at sufficiently frequent intervals to determine if the equipment is clean and in satisfactory condition. A cleaning regimen shall be posted to ensure proper cleaning procedures between inspection periods.
- (k)Internal return tubular heat exchangers. Internal return tubular heat exchangers shall meet the 3-A Sanitary Standards for Construction and Installation.
- Pumps. Pumps used for milk and dairy products shall be of the sanitary type and constructed to meet 3-A Sanitary Standards. Unless pumps are specifically designed for effective cleaning in place they shall be disassembled and thoroughly cleaned after use.
- (m)Homogenizers. Homogenizers and high pressure pumps of the plunger type shall meet the 3-A Sanitary Standards.
- (n)New equipment and replacements. New equipment and replacements, including all plastic parts and rubber and rubberlike materials for parts and gaskets having product contact surfaces, shall meet the then current 3-A Sanitary Standards. If 3-A Sanitary Standards are not available, such equipment and replacements shall meet the general requirements of this section.
- (o)Vacuum chamber. The vacuum chamber, as used for flavor control, shall be made of stainless steel or other equally noncorrosive metal. The unit shall be constructed to facilitate cleaning and all product contact surfaces shall be accessible for inspection. It shall be equipped with a vacuum breaker and a check valve at the product discharge line. Only steam which meets the requirements for culinary steam shall be used. The incoming steam supply shall be regulated by an automatic solenoid valve which will cut off the steam supply in the event the flow
23