• Separators. All product contact surfaces of separators shall be free from rust and pits and insofar as practicable shall be of stainless steel or other equally noncorrosive metals.
  • Coil or dome-type batch pasteurizers. Coil or dome-type batch pasteurizers shall be stainless steel lined and if the coil is not stainless steel or other equally noncorrosive metal it shall be properly tinned over the entire surface. Sanitary seal assemblies at the shaft ends of coil vats shall be of the removable type, except that existing equipment not provided with this type gland will be acceptable if the packing glands are maintained and operated without adverse effects. New or replacement units shall be provided with removable packing glands. Dome-type Pasteurizer agitators shall be stainless steel except that any nonmetallic parts shall meet 3-A Sanitary Standards for Plastic or Rubber and Rubberlike Materials, as applicable. Each pasteurizer used for heating product at 165circF. or lower for 30 minutes or less shall be equipped with space heating equipment and the necessary thermometers to ensure a temperature at least 5circF. above that required for pasteurization of the product. There shall be adequate means of controlling the temperature of the heating medium. Batch pasteurizers shall have temperature indicating and recording devices.
  • High-temperature, short-time pasteurizers. When pasteurization is intended or required, an approved timing pump or device recorder-controller, automatic flow diversion valve and holding tube or its equivalent, if not a part of the existing equipment, shall be installed on all HTST equipment used for pasteurization, to assure complete pasteurization. The entire facility shall meet the 3-A Accepted Practices for the Sanitary Construction, Installation, Testing, and Operation of High-Temperature, Short-Time Pasteurizers. After the HTST unit has been tested according to the 3-A Accepted Practices, the timing pump or device and the recorder controller shall be sealed at the correct setting to assure pasteurization. Sealing of the HTST unit shall be performed by the control authority having jurisdiction. The HTST pasteurizer shall be tested initially upon installation, and whenever any alteration or replacement is made which affects the proper operation of the instrument or device. When direct steam pasteurizers are used, the steam, prior to entering the product, shall be conducted through a steam strainer and a steam purifier equipped with a steam trap and only steam meeting the requirements for culinary steam shall be used.
  • Thermometers and recorders.
  • Indicating thermometers.
  • Long-stem indicating thermometers which are accurate within 0.5circ F., plus or minus, for the applicable temperature range, shall be provided for checking the temperature of pasteurization and cooling of products in vats and checking the accuracy of recording thermometers.
  • Short-stem indicating thermometers, which are accurate within 0.5circ F., plus or minus, for the applicable temperature range, shall be installed in the proper stationary position in all HTST, and dome-type pasteurizers. Storage tanks where temperature readings are required shall have thermometers which are accurate within 2.0circ F., plus or minus.
  • Air-space indicating thermometers, where applicable, which are accurate within 1.00 F., plus or minus, for the proper temperature range shall also be installed above the