THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF PROFESSIONAL DE SERVICES, L.L.C., AND IS NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER PIT WITHOUT THE WRITTEN AUTHORIZATION OF PROFESSIONAL DESIGN SERVICES. L.L.
TREE), AS WELL AS CULTURAL REQUIREMENTS, INCLUDING WATERING AND FERTILIZATION.
FENCING SHALL BE INSTALLED AND APPROVED BY THE TOWNSHIP TREE SPECIALIST PRIOR TO ANY CLEARING OR EXCAVATION. TREE FENCING TO REMAIN UNTIL PROTECTION AUTHORIZED TO BE REMOVED BY THE TOWNSHIP TREE SPECIALIST OR AFTER THE FINAL CERTIFICATE OF OCCUPANCY IS ISSUED.
6' HIGH, 2" STEEL 'U' CHANNEL OR 2"X2" TIMBER POSTS, MAXIMUM 6' ON CENTER
ORANGE PLASTIC MESH CONSTRUCTION FENCE - MINIMUM 4' HEIGHT USE 8" WIRE 'U' TO SECURE FENCE BOTTOM 1/3 OF POST HEIGHT BELOW GROUND
NOT TO SCALE
DO NOT HEAVILY PRUNE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO- DOMINANT LEADERS AND BROKEN OR DEAD BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED; HOWEVER DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. NEVER CUT CENTRAL LEADER OR TRUNK.
MULCH 4" MINIMUM; DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK
- PACKED SAUCER SHALL BE 4" HIGHER THAN FINISHED GRADE. SAUCERS ON SLOPES SHALL BE LEVEL AT THE TOP AND PERPENDICULAR TO THE TREE TRUNK
TWO 2"x2" MINIMUM STAKES PLACED OUTSIDE HOLE, DRIVEN 2' MINIMUM INTO UNDISTURBED SOIL, PLACED IN LINE WITH PREVAILING WINDS. ATTACH TO TREE WITH A DOUBLE STRAND OF #12 GAUGE GALVANIZED WIRE COVERED BY RUBBER OR PLASTIC HOSE WHERE THE WIRE COMES INTO CONTACT WITH THE TREE, OR TREE TIES ESPECIALLY MANUFACTURED FOR THIS PURPOSE. SEE NOTE 1
CUT AND REMOVE BURLAP AND STRING FROM TOP 1/3 OF ROOT BALL; ALL WIRE BASKETS TO BE REMOVED PRIOR TO BACKFILLING OF THE
BE REMOVED PRIOR TO BACKFILLING OF THE PLANTING PIT
PLANTING MIXTURE INCORPORATING A MINIMUM 25% ORGANIC MATTER BY VOLUME
PLANTING HOLE SHALL BE A MINIMUM OF 12" LARGER IN DIAMETER AND 6" DEEPER THAN THE SOIL BALL OR ROOT MASS
— COMPACTED SUBGRADE
NOTE: 1 THE LOOP IN CONTACT WITH THE TREE SHALL BE LOOSE ENOUGH TO PERMIT GROWTH
DO NOT HEAVILY PRUNE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND BROKEN OR DEAD BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED; HOWEVER DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. NEVER CUT CENTRAL LEADER OR TRUNK.
DRAINING SOILS, SET ROOT BALL SEVERAL INCHES HIGHER THAN GRADE. AFTER SETTLEMENT, TREE SHALL BE PLUMB AND BEAR SAME RELATIONSHIP TO FINISHED GRADE AS IT DID TO ITS NURSERY AND FIELD GROWN GRADE. CAREFULLY CUT AND REMOVE BURLAP AND TWINE FROM TOP 1/3 OF ROOT BALL, AND/OR CAREFULLY CUT TOP BANDS OF WIRE BASKET FROM TOP 1/3 OF ROOT BALL.
— TWO 2"x2" MINIMUM STAKES PLACED OUTSIDE HOLE, DRIVEN 2' MINIMUM INTO UNDISTURBED SOIL, PLACED IN LINE WITH PREVAILING WINDS. ATTACH TO TREE WITH A DOUBLE STRAND OF #12 GAUGE GALVANIZED WIRE COVERED BY RUBBER OR PLASTIC HOSE WHERE THE WIRE COMES INTO CONTACT WITH THE TREE, OR TREE TIES ESPECIALLY MANUFACTURED FOR THIS PURPOSE. SEE NOTE 2
MULCH 4" MINIMUM; DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK
PACKED SAUCER SHALL BE 4" HIGHER THAN FINISHED GRADE. SAUCERS ON SLOPES SHALL BE LEVEL AT THE TOP & PERPENDICULAR TO THE TREE TRUNK
CUT & REMOVE BURLAP AND STRING FROM TOP 1/3 OF ROOT BALL
PLANTING MIXTURE INCORPORATING A MINIMUM 25% ORGANIC MATTER BY VOLUME
COMPACTED SUBGRADE
PLANTING HOLE SHALL BE A MINIMUM OF 12" LARGER
PLANTING HOLE SHALL BE A MINIMUM OF 12" LARGER IN DIAMETER AND 6" DEEPER THAN THE SOIL BALL OR ROOT MASS
NOTE:
NOT TO SCALE
N THE ENTIRE BED
-SCARIFY BOTTOM OF BED TO BIND WITH NEW SOIL
CUSTOMER NAME
PROJECT NAME TYPE
DATE CATALOG NUMBER
PRODUCT ID
E=Evolv
AL=Area Light
S=Standard
| GENERATION | VOLTAGE | OPTICAL CODE | DISTRIBUTION | CRI | CCT | DIMMING* | CONTROLS | MOUNTING ARM | COLOR | OPTIONS |
|---|---|---|---|---|---|---|---|---|---|---|
| 03 | 0'=120-277V | Cx=7600M | SM= Symmetric Medium | 7=70 (min) | 30th= 3000K | N=Dimming thru PE receptacle | A=ANSI C136.41 7-Pin Receptacle (No Control) | CTe= Integral Slipfitter: Standard | BLOCK= Black | F=Fusing |
| H'=347-480V | Dx=10000 lmb | SW= Symmetric Wide | 40= 4000K | D=External Dimming 18/2 3 ft Cable | D=ANSI C136.417-Pin Receptacle with Shorting Cap | D1f= Universal Mounting Arm: Fitted for round or square poles mounting | DKBZ= Dark Bronze | H= Motion Sensor3, 14, 16 (Sensor Switch) | ||
| E'M=277-480V | Fx=15000 lm | SH= Symmetric High Angle | 50= 5000K | X=Non dimming, no external dimming leadsg | E3= ANSI C136.41 7-pin with Non-Dimming PE Control | K1e,g= Knuckle Slipfitter: For 1.9 In - 2.3 in OD Tenon | GRAY= Gray | H1= LightGrid w/ WattStopper14 | ||
| Hx=20000 lm | AF= Asymmetric Forward | S14,g= Knuckle Slipfitter: For 2.9 In - 3.0 in OD Tenon | WHITE= White | H2= Daintree enabled motion sensor14,g | ||||||
| 1=120V | Jx=25000 lm | AH= Asymmetric High Angle | VHe= Knuckle Wall Mount | H4= Motion Sensor (WattStopper)14 | ||||||
| 2=208V | Kx=30000 lm | AW= Asymmetric Wide | J=cLIL/Canada | |||||||
| 3=240V | AN= Asymmetric Narrow/Auto | L= Tool-Less Entry | ||||||||
| 4=277V | R= Enhanced Surge Protection (10KV/5kA) | |||||||||
| D=347V | S1g= Rotated Left | |||||||||
| 5=480V | S2g= Rotated Right | |||||||||
| T= Extreme Surge Protection (20KV/10kA) | ||||||||||
| U7= DALI Programmable |
^1 Not Available with Fusing. Must Choose a Discrete Voltage with "F" Option Code ^2 Note Standard Dimming is 0-10V ^3 Not available in 277-480V ^4 Supplied with 3ft leads ^5 Supplied with 16/3 ft Cable ^6 Restricted Aiming Angle of 0-45° ^7 Compatible with LightGrid Wireless Control Nodes. Not Compatible with Motion Sensor Control ^8 Not available in 347V, 480V or 347-480V ^9 Only available with F,H,J,K optics ^10 Recommended for installations within 750 feet from coast. Lead time varies, check with factory. ^11 Select 3000K CCT for IDA approved fixtures. ^12 For aimed left of right light distribution orientation, as assembled in manufacturing. Not applicable for Symmetric Distributions ^13 Required for CX optical codes only, not available for other optic codes ^14 Not available with DALI ^15 DALI option not available with 347V, 480V, or 347-480V ^16 Not available with 20kV/10kA SPD
XXX = Special Options
Current
| LED.com | Page 2 of 9 |
|---|---|
| © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. | (Rev 09/25/23) |
| OLP31H_R04 |
CUSTOMER NAME
PROJECT NAME
DATE TYPE
CATALOG NUMBER
TYPE
TYPE V
TYPE IV
TYPE III
TYPE II
OPTIC CODE DISTRIBUTION TYPICAL INITIAL LUMENS TYPICAL SYSTEM WATTAGE BUG RATINGS
3000K 4000K & 5000K 120-277 & 347-480V 3000K 4000 & 5000K
B-U-G B-U-G
C5 Symmetric Medium (SM) 7300 7500 46 B3-U0-G1 B3-U0-G1
D5 Symmetric Medium (SM) 9600 10000 64 B3-U0-G1 B3-U0-G1
F5 Symmetric Medium (SM) 14700 15000 101 B4-U0-G2 B4-U0-G2
H5 Symmetric Medium (SM) 19600 20000 140 B4-U0-G2 B4-U0-G2
J5 Symmetric Medium (SM) 24500 25000 186 B4-U0-G2 B4-U0-G2
K5 Symmetric Medium (SM) 29400 30000 239 B5-U0-G3 B5-U0-G3
C5 Symmetric Wide (SW) 7300 7500 46 B2-U0-G1 B2-U0-G1
D5 Symmetric Wide (SW) 9800 10100 64 B3-U0-G1 B3-U0-G1
F5 Symmetric Wide (SW) 14700 15100 101 B3-U0-G2 B3-U0-G2
H5 Symmetric Wide (SW) 19700 20200 140 B4-U0-G2 B4-U0-G2
J5 Symmetric Wide (SW) 24600 25200 186 B4-U0-G2 B4-U0-G2
K5 Symmetric Wide (SW) 29600 30300 239 B5-U0-G2 B5-U0-G2
C5 Symmetric High Angle (SH) 7000 7200 46 B3-U0-G1 B3-U0-G1
D5 Symmetric High Angle (SH) 9400 9600 64 B3-U0-G2 B3-U0-G2
F5 Symmetric High Angle (SH) 14200 14500 101 B4-U0-G2 B4-U0-G2
H5 Symmetric High Angle (SH) 18900 19300 140 B4-U0-G2 B4-U0-G2
J5 Symmetric High Angle (SH) 23600 24100 186 B5-U0-G3 B5-U0-G3
K5 Symmetric High Angle (SH) 28400 29000 239 B5-U0-G3 B5-U0-G3
C4 Asymmetric Forward (AF) 7300 7500 50 B1-U0-G2 B1-U0-G2
D4 Asymmetric Forward (AF) 9800 10000 70 B2-U0-G2 B2-U0-G2
F4 Asymmetric Forward (AF) 14700 15000 116 B2-U0-G2 B2-U0-G2
H4 Asymmetric Forward (AF) 19600 20000 140 B3-U0-G3 B3-U0-G3
J4 Asymmetric Forward (AF) 24500 25000 186 B3-U0-G3 B3-U0-G3
K4 Asymmetric Forward (AF) 29400 30000 239 B3-U0-G4 B3-U0-G4
C4 Asymmetric High Angle (AH) 7000 7200 50 B2-U0-G2 B2-U0-G2
D4 Asymmetric High Angle (AH) 9400 9600 70 B2-U0-G2 B2-U0-G2
F4 Asymmetric High Angle (AH) 14200 14500 116 B3-U0-G3 B3-U0-G3
H4 Asymmetric High Angle (AH) 18900 19300 140 B3-U0-G3 B3-U0-G4
J4 Asymmetric High Angle (AH) 23600 24100 186 B3-U0-G4 B3-U0-G4
K4 Asymmetric High Angle (AH) 28400 29000 239 B3-U0-G4 B3-U0-G4
C3 Asymmetric Wide (AW) 7300 7500 50 B2-U0-G1 B2-U0-G1
D3 Asymmetric Wide (AW) 8900 10100 70 B2-U0-G2 B2-U0-G2
F3 Asymmetric Wide (AW) 14700 15100 116 B2-U0-G2 B2-U0-G2
H3 Asymmetric Wide (AW) 19600 20200 140 B3-U0-G2 B3-U0-G3
J3 Asymmetric Wide (AW) 24600 25200 186 B3-U0-G3 B3-U0-G3
K3 Asymmetric Wide (AW) 29600 30300 239 B3-U0-G3 B3-U0-G3
C2 Asymmetric Narrow/Auto (AN) 7300 7500 50 B3-U0-G2 B2-U0-G2
D2 Asymmetric Narrow/Auto (AN) 9800 10100 70 B2-U0-G2 B2-U0-G2
F2 Asymmetric Narrow/Auto (AN) 14700 15100 116 B2-U0-G2 B3-U0-G3
H2 Asymmetric Narrow/Auto (AN) 19700 20200 140 B3-U0-G3 B3-U0-G3
J2 Asymmetric Narrow/Auto (AN) 24600 25200 186 B3-U0-G3 B3-U0-G3
K2 Asymmetric Narrow/Auto (AN) 29600 30300 239 B3-U0-G3 B3-U0-G3
For additional information on Non-Shielded and Shielded EALS files, please refer to LED.com
Current
| LED.com | Page 3 of 9 |
|---|---|
| © 2023 Current Lighting Solutions, LLC All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. | (Rev 09/25/23) |
| OLP3H1_R04 |
INTEGRAL SLIPFITTER: CI
EVOLVE EALS Series LED Outdoor Area Light
CUSTOMER NAME _____ PROJECT NAME _____ DATE _____ TYPE _____ CATALOG NUMBER _____
KEY MAP SCALE: 1" = 2000'
CONSULTING ENGINEERS, LAND SURVEYORS, PLANNERS, ENVIRONMENTAL SCIENTISTS, CONSTRUCTION SERVICES 1245 AIRPORT ROAD, SUITE 1, LAKEWOOD, NEW JERSEY 08701 PHONE 732 363 0060 FAX 732 363 0073 NEW JERSEY STATE BOARD OF P.E. & L.S. CERTIFICATE OF AUTHORIZATION NO. 24GA28125400 IAN M BORDEN, PP N.J. PROFESSIONAL PLANNER LICENSE #33LI00617400 IBORDEN@PDS-NJ.COM WILLIAM A. STEVENS, PE, PP PROFESSIONAL ENGINEER, NEW JERSEY LIC. #3915 PROFESSIONAL PLANNER, NEW JERSEY LIC. #5394 BSTEVENES@PDS-NJ.COM GRAHAM J. MACFARLANE, PE, PP, CME PROFESSIONAL ENGINEER, NEW JERSEY LIC. #37110 PROFESSIONAL PLANNER, NEW JERSEY LIC. #6104 GRAHAM@PDS-NJ.COM STEVEN METELSKI, JR., PLS N.J. PROFESSIONAL LAND SURVEYOR LICENSE #43393 STEVENM@PDS NLICM
PROFESSIONAL ENGINEER, NEW JERSEY LIC. #39915 PROFESSIONAL PLANNER, NEW JERSEY LIC. #5394
PRELIMINARY & FINAL SITE PLANS
FOR
TAX BLOCK 22203 TAX LOT 11
KRISTIN 1/22/24 H:\PROJECTS\3236
Current LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions. Page 7 of 9 (Rev 09/25/23) OLP3H1_R04
TOWNSHIP OF JACKSON
OCEAN COUNTY NEW JERSEY
| SCALE: | AS SHOWN | JOB NUMBER: | 323617 |
|---|---|---|---|
| DRAWN BY: | KNL | DATE: | MARCH 17, 2023 |
| DESIGN/CALC'D BY: | IMB | SHEET: 9 | 15 |
| CHECKED BY: | WAS |