THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF PROFESSIONAL SERVICES, L.L.C., AND IS NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER P WITHOUT THE WRITTEN AUTHORIZATION OF PROFESSIONAL DESIGN SERVICES, L.L.
HEADWALL- ENDWALL FLARED END SECTION REINFORCED CONCRETE PIPE SCHEDULE
NOT TO SCALE
NOTE:
SAND FILTER BED
NTS
FABRIC ON TOP
「——〒〒〒〒
2. DESIGN AND PROPER FUNCTION OF RECHARGE SYSTEM RELIES ON ADEQUATE PERMEABILITY OF SOILS BENEATH THE RECHARGE SYSTEM. EXCAVATION BENEATH INVERT OF PERFORATED PIPES SHALL BE CARRIED TO THE ELEVATION AT WHICH PERMEABILITY SAND AND GRAVEL IS ENCOUNTERED WHICH HAS A PERMEABILITY RATE OF AT LEAST 20 INCHES/HOUR. RECHARGE PIPE
NTS
ALL EDGES TO BE CHAMFERED 1"
D=DIAMETER OF PIPE.
PLAN VIEW
END VIEW
THE TERMINUS FOR OUTLET AND INLET APRONS SHALL BE SET BY EXTENDING THE PIPE GRADE AHEAD AND BACK RESPECTIVELY.
THE TERMINUS FOR OUTLET AND INLET APRONS SHALL BE SET BY EXTENDING THE PIPE GRADE AHEAD AND BACK RESPECTIVELY.
THE TERMINUS FOR OUTLET AND INLET APRONS SHALL BE SET BY EXTENDING THE PIPE GRADE AHEAD AND BACK RESPECTIVELY.
FOR ARCH PIPE, THE SPAN SHALL BE SUBSTITUTED FOR "D"
EXPOSED PORTIONS OF WALL TO BE RUBBED & FLOATED TO REMOVE FORM MARKS.
USE CLASS "B" CONCRETE
| DESCRIPTION | "D" | "L" | "W" | "A" | "H" | INV. B | T/W |
|---|
| HEADWALL | 12" | 21" | 36" | 24" | 24" | | |
|---|
| HEADWALL | 15" | 26" | 45" | 30" | 27" | | |
|---|
| HEADWALL | 18" | 31" | 54" | 36" | 30" | | |
|---|
| HEADWALL | 24" | 42" | 72" | 48" | 36" | | |
|---|
| HEADWALL | 30" | 52" | 90" | 60" | 42" | | |
|---|
| HEADWALL | 36" | 62" | 108" | 72" | 48" | | |
|---|
| HEADWALL | 48" | 83" | 144" | 96" | 60" | | |
|---|
OUTLET END
SCALE: 3/8"=1'-0
KRISIN 1/22/24
H:\PROJECTS\323617 < 323617 S09 CONSTRUCTION DETAILS >
KEY MAP
SCALE: 1" = 2000'
2 01/22/2024 REV PER PLANNING BOARD COMMENTS KNL
1 11/20/2023 GENERAL REVISIONS KNL
No. DATE DESCRIPTION BY
PDS
CONSULTING ENGINEERS, LAND SURVEYORS, PLANNERS, ENVIRONMENTAL SCIENTISTS, CONSTRUCTION SERVICES
1245 AIRPORT ROAD, SUITE 1, LAKEWOOD, NEW JERSEY 08701
PHONE 732 363 0060 FAX 732 363 0073
NEW JERSEY STATE BOARD OF P.E. & L.S.
CERTIFICATE OF AUTHORIZATION NO. 24GA28125400
IAN M BORDEN, PP
N.J. PROFESSIONAL PLANNER LICENSE #33LI00617400
IBORDEN@PDS-NJ.COM
WILLIAM A. STEVENS, PE, PP
PROFESSIONAL ENGINEER, NEW JERSEY LIC. #39915
PROFESSIONAL PLANNER, NEW JERSEY LIC. #5394
BSTEVENES@PDS-NJ.COM
GRAHAM J. MACFARLANE, PE, PP, CME
PROFESSIONAL ENGINEER, NEW JERSEY LIC. #37110
PROFESSIONAL PLANNER, NEW JERSEY LIC. #6104
GRAHAM@PDS-NJ.COM
STEVEN METELSKI, JR., PLS
N.J. PROFESSIONAL LAND SURVEYOR LICENSE #43393
STEVENEN@PDS-NJ.COM
[F2]
WILLIAM A. STEVENS, J.P.E. P.P.
PRELIMINARY & FINAL SITE PLANS
CONSTRUCTION DETAILS STORMWATER
FOR TAX BLOCK 22203 TAX LOT 11
TOWNSHIP OF JACKSON
| SCALE: | AS SHOWN | JOB NUMBER: | 323617 |
|---|
| DRAWN BY: | KNL | DATE: | MARCH 17, 2023 |
|---|
| DESIGN/CALC'D BY: | IMB | SHEET: 12 | 15 |
|---|
| CHECKED BY: | WAS |
|---|