• Identify electrical and telephone panel room locations
  • Locate electrical devices for typical areas including power receptacles, computer, telephone, TV Light switches, closed circuit TV, fire alarm, security, A/V and intercom devices
  • Locate exit and emergency lighting and fire alarm devices (consider ADA requirements)
  • Consider access and replacement requirements with all utility room layouts
  • Coordinate ceiling plenum space with architectural, plumbing, fire protection, mechanical, structural and specialty systems
  • Update design calculations to include power consuming equipment and load characteristics
  • Site lighting, locate and identify all lighting fixtures

b. Catalog Cuts:

  • Light fixtures
  • Fire alarm devices
  • Special equipment

H. OTHER REQUIREMENTS:

  • a. Specialty consultants:

All specialty consultants should provide the same level of information which is required for MEP disciplines, including the following specialty consultants: fueling and equipment, security (access control and CCTV), A/V, signage / wayfinding

b. Specifications:

  • Final specifications
  • Front end documents (Division 0 and 1) to be provided by airport, modified by consultant and coordinated with technical specifications
  • When product is specified, three manufacturers must be listed as acceptable or the airport will agree if circumstances require a product to be sole sourced

I. LANDSCAPING:

  • Tree and vegetation protection and construction limits
  • Site grading plan with existing and proposed grading including contours and spot elevations
  • Consideration is to be given to the topographic information for drainage
  • Typical site sections thru exterior walls
  • Site plan indicating lawn and plantings
  • Irrigation plan including typical details and proposed tie-in points.

10