SRQ Quick Turnaround and Maintenance Facilities Sarasota Bradenton International Airport Sarasota, Florida
Revised 12.23.2020
Identify electrical and telephone panel room locations
Locate electrical devices for typical areas including power receptacles, computer, telephone, TV Light switches, closed circuit TV, fire alarm, security, A/V and intercom devices
Locate exit and emergency lighting and fire alarm devices (consider ADA requirements)
Consider access and replacement requirements with all utility room layouts
Coordinate ceiling plenum space with architectural, plumbing, fire protection, mechanical, structural and specialty systems
Update design calculations to include power consuming equipment and load characteristics
Site lighting, locate and identify all lighting fixtures
b. Catalog Cuts:
Light fixtures
Fire alarm devices
Special equipment
H. OTHER REQUIREMENTS:
a. Specialty consultants:
All specialty consultants should provide the same level of information which is required for MEP disciplines, including the following specialty consultants: fueling and equipment, security (access control and CCTV), A/V, signage / wayfinding
b. Specifications:
Final specifications
Front end documents (Division 0 and 1) to be provided by airport, modified by consultant and coordinated with technical specifications
When product is specified, three manufacturers must be listed as acceptable or the airport will agree if circumstances require a product to be sole sourced
I. LANDSCAPING:
Tree and vegetation protection and construction limits
Site grading plan with existing and proposed grading including contours and spot elevations
Consideration is to be given to the topographic information for drainage
Typical site sections thru exterior walls
Site plan indicating lawn and plantings
Irrigation plan including typical details and proposed tie-in points.
10