SRQ Quick Turnaround and Maintenance Facilities Sarasota Bradenton International Airport Sarasota, Florida
Revised 12.23.2020
Include major building sections, identify column lines, openings and relationships between floor, ceilings, roof structure and mechanical systems
Vertical dimensions including floor to roof and ceiling heights
Finished grades around the building
Typical and major wall sections or assembly details
e. Details:
Large scale typical details of exterior wall assemblies, parapets to foundation
Large scale typical details of major foundation and perimeter treatment
Typical window and door details (i.e.: head, jamb and sill conditions)
Typical interior and exterior columns details
f. Interior Elevations:
g. Schedules:
Key enlarged plans (+/- 1 1/4″)
Major casework elevations and profiles
Partition types
Elevations of significant interior spaces
Interior finish schedule
Door and frame schedules
Door hardware schedule
Window and glazing schedule
C. CODE ANALYSIS:
a. Code footprint:
Life safety plans
Include all fire rated partitions
D. STRUCTURAL:
Structural Plans:
Fully-dimensioned foundation plan including interior and perimeter foundations, footings, wall beams and grade beams
b. Structural sections and details:
Fully-dimensioned framing plans for all floors and roofs including major member sizes noted or scheduled, typical and maximum column sizes
Locate columns, beams, purlins and joists, etc.
Location of any in-floor electrical or IT systems
Major penetrations (i.e. slab openings, pits, trench drains, located on drawings
Expansion joints located
7