B. ARCHITECTURAL:
a. Floor Plans:
- ii.Internal partitions drawn, located and dimensioned
- iii.All casework and other equipment called out on plans
- iv.Major mechanical/electrical systems determined and their requirements reflected and indicated on the plans including, louvers, areaways and utility entrances
- v.Locate all plumbing fixtures in restrooms
- vi.All rooms named and numbered
- vii.Locate exterior and interior doors and windows
- viii.Locate typical and fire rated partition types
- ix.All keyed references: match lines, building sections, enlarged plans, keyed notes, etc.
- x.Finish floor elevations noted
- xi.Expansion joints indicated (if needed)
- xii.Toilet cores drawn to larger scale (+/- 1/4"), dimensioned and keyed to larger plans
- xiii.Plan and elevations of featured areas drawn to a larger scale (+/- 1/4) with all surfaces shown and called out and keyed to larger plans
- xiv.Traffic topping/coating plans indicating limits
b. Reflected Ceiling Plans:
Provide a reflected ceiling plan for all finished spaces which includes:
- i.Located lighting fixtures
- ii.Located ceiling mounted grilles/registers
- iii.Located any remaining ceiling mounted devices
- iv.Soffits/bulkheads, skylights
- v.Identify major ceiling materials
- vi.Identify all areas with exposed structure
c. Building Elevations:
- i.Building elevations including roof structures and foundations
- ii.Identify and locate all exterior windows and doors
- iii.Identify floor and roof levels, vertical dimensions and overall building heights
- iv.Column center lines
- v.Locate expansion joints and major panel joints
- vi.All materials noted with demarcation of materials shown
- vii.Detailed elevations at a larger scale (+/- 1/4”) as necessary to explain design intent (entrances, special metal panels or masonry, building canopy, etc.)
- viii.Major keyed references: match lines, building sections, wall sections
- d.Building and Wall Sections:
6