{
    "document_id": 16823,
    "page": 5,
    "width_pt": 1191,
    "height_pt": 842,
    "rotation": 270,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 16934,
    "item_count": 21,
    "counts_by_type": {
        "figure": 8,
        "footer": 2,
        "footnote": 10,
        "header": 1
    },
    "build_ms": 15,
    "items": [
        {
            "id": "p5.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 40.076,
                "t": 710.505,
                "r": 139.186,
                "b": 697.5474
            },
            "text": "Flue gas treatment",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p5.2",
            "order": 2,
            "type": "figure",
            "bbox": {
                "l": 289.911,
                "t": 804.875,
                "r": 416.169,
                "b": 670.34
            },
            "text": "",
            "attrs": {
                "source": "pdf_image"
            }
        },
        {
            "id": "p5.3",
            "order": 3,
            "type": "figure",
            "bbox": {
                "l": 38.8761,
                "t": 693.2283,
                "r": 544.2652,
                "b": 191.7236
            },
            "text": "",
            "attrs": {
                "block_label": "image",
                "embedded_text": "2. Gases from the\nTurbosorp® reactor\ntower are drawn into\none of three fabric 5. An induced draught\nbag filters which each fan for each of the\nconsist of 2,048 6m three lines draws\nlong cylindrical fibre clean cooled gas up\nbags on steel wire the 85 metre stack\ncages. The clean where it is discharged\ngases pass through 4. Clean hot gas is drawn into the atmosphere.\nthe filters and the Air 3. Compressed air out of the fabric filter bags Emissions equipment\nPollution Control pulses shake off the through a heat exchanger continually monitors\nResidue (APCR) APCR into silos. The which allows heat to be plant performance in\ncollects on the outer APCR is removed from transferred from the gas relation to the\nsurface of the bags. the site by road tanker. into the boiler feed water. environmental permit.\nWestern Riverside Waste"
            }
        },
        {
            "id": "p5.4",
            "order": 4,
            "type": "figure",
            "bbox": {
                "l": 570.079,
                "t": 512.803,
                "r": 697.556,
                "b": 386.212
            },
            "text": "",
            "attrs": {
                "source": "pdf_image"
            }
        },
        {
            "id": "p5.5",
            "order": 5,
            "type": "figure",
            "bbox": {
                "l": 1020.6172,
                "t": 710.0251,
                "r": 1147.3244,
                "b": 618.3625
            },
            "text": "",
            "attrs": {
                "block_label": "image",
                "embedded_text": "steam leaves the turbine"
            }
        },
        {
            "id": "p5.6",
            "order": 6,
            "type": "figure",
            "bbox": {
                "l": 644.815,
                "t": 610.684,
                "r": 1138.6853,
                "b": 444.8755
            },
            "text": "",
            "attrs": {
                "block_label": "image",
                "embedded_text": "directed onto rings of fixed blades at the same speed as the turbine. condenser. The resulting\ncausing the turbine to rotate at This produces high voltage electricity condensate is then returned to the\nspeed. which is sent to the 132kv substation boilers as boiler feed water.\nand on to the National Grid. The plant\nproduces enough electricity to power\naround 100,000 homes."
            }
        },
        {
            "id": "p5.7",
            "order": 7,
            "type": "figure",
            "bbox": {
                "l": 651.0544,
                "t": 419.9202,
                "r": 782.3212,
                "b": 288.6651
            },
            "text": "",
            "attrs": {
                "block_label": "image",
                "embedded_text": "reuse, recycling and energy"
            }
        },
        {
            "id": "p5.8",
            "order": 8,
            "type": "figure",
            "bbox": {
                "l": 824.077,
                "t": 419.9202,
                "r": 958.4634,
                "b": 289.1451
            },
            "text": "",
            "attrs": {
                "block_label": "image",
                "embedded_text": "in your area – our way"
            }
        },
        {
            "id": "p5.9",
            "order": 9,
            "type": "figure",
            "bbox": {
                "l": 1001.6591,
                "t": 418.9604,
                "r": 1131.006,
                "b": 289.1451
            },
            "text": "",
            "attrs": {
                "block_label": "image"
            }
        },
        {
            "id": "p5.10",
            "order": 10,
            "type": "footnote",
            "bbox": {
                "l": 39.356,
                "t": 679.7908,
                "r": 313.8884,
                "b": 627.4808
            },
            "text": "1. Flue gases leave the boiler and pass into a Turbosorp® reactor tower where hydrated lime, powdered activated carbon and water are injected into the swirling gas flow. These help neutralise acids and capture heavy metal particles.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.11",
            "order": 11,
            "type": "footnote",
            "bbox": {
                "l": 45.3554,
                "t": 593.6472,
                "r": 155.0244,
                "b": 457.3531
            },
            "text": "DID YOU KNOW?\nThe Air Pollution Control Residue (APCR) is a by-product of the combustion process and accounts for approximately 4% of the facility's waste throughput.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.12",
            "order": 12,
            "type": "footnote",
            "bbox": {
                "l": 39.356,
                "t": 272.8282,
                "r": 140.8658,
                "b": 84.9439
            },
            "text": "2. Gases from the Turbosorp® reactor tower are drawn into one of three fabric bag filters which each consist of 2,048 6m long cylindrical fibre bags on steel wire cages. The clean gases pass through the filters and the Air Pollution Control Residue (APCR) collects on the outer surface of the bags.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.13",
            "order": 13,
            "type": "footnote",
            "bbox": {
                "l": 438.1958,
                "t": 235.8752,
                "r": 542.1054,
                "b": 84.9439
            },
            "text": "5. An induced draught fan for each of the three lines draws clean cooled gas up the 85 metre stack where it is discharged into the atmosphere. Emissions equipment continually monitors plant performance in relation to the environmental permit.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.14",
            "order": 14,
            "type": "footnote",
            "bbox": {
                "l": 298.05,
                "t": 161.4893,
                "r": 417.5579,
                "b": 85.1838
            },
            "text": "4. Clean hot gas is drawn out of the fabric filter bags through a heat exchanger which allows heat to be transferred from the gas into the boiler feed water.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.15",
            "order": 15,
            "type": "footnote",
            "bbox": {
                "l": 166.0633,
                "t": 148.7717,
                "r": 270.2128,
                "b": 84.7039
            },
            "text": "3. Compressed air pulses shake off the APCR into silos. The APCR is removed from the site by road tanker.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.16",
            "order": 16,
            "type": "footnote",
            "bbox": {
                "l": 635.9359,
                "t": 711.7048,
                "r": 782.0812,
                "b": 697.3075
            },
            "text": "Steam turbine and generator",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.17",
            "order": 17,
            "type": "footnote",
            "bbox": {
                "l": 635.696,
                "t": 279.5469,
                "r": 787.8406,
                "b": 215.4791
            },
            "text": "1. High pressure steam from each of the three boiler drums is directed onto rings of fixed blades causing the turbine to rotate at high speed.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.18",
            "order": 18,
            "type": "footnote",
            "bbox": {
                "l": 806.3188,
                "t": 279.7868,
                "r": 974.0619,
                "b": 178.5261
            },
            "text": "2. The steam turbine is coupled to the electric generator which rotates at the same speed as the turbine. This produces high voltage electricity which is sent to the 132kv substation and on to the National Grid. The plant produces enough electricity to power around 100,000 homes.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.19",
            "order": 19,
            "type": "footnote",
            "bbox": {
                "l": 987.0206,
                "t": 279.5469,
                "r": 1147.0844,
                "b": 216.4389
            },
            "text": "3. Exhaust steam leaves the turbine and is cooled in an air cooled condenser. The resulting condensate is then returned to the boilers as boiler feed water.",
            "attrs": {
                "block_label": "vision_footnote"
            }
        },
        {
            "id": "p5.20",
            "order": 20,
            "type": "footer",
            "bbox": {
                "l": 396.4401,
                "t": 29.2744,
                "r": 562.7433,
                "b": 17.5167
            },
            "text": "Western Riverside Waste Authority",
            "attrs": {
                "block_label": "footer"
            }
        },
        {
            "id": "p5.21",
            "order": 21,
            "type": "footer",
            "bbox": {
                "l": 627.0568,
                "t": 29.5144,
                "r": 979.3413,
                "b": 16.5569
            },
            "text": "Waste reuse, recycling and energy recovery in your area – our way forward",
            "attrs": {
                "block_label": "footer"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}