    "document_id": 15922,
    "page": 226,
    "width_pt": 595.32,
    "height_pt": 841.92,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 16036,
    "item_count": 22,
    "counts_by_type": {
        "figure": 1,
        "footer": 1,
        "heading": 2,
        "list": 2,
        "list_item": 11,
        "text": 5
    },
    "build_ms": 2,
    "items": [
        {
            "id": "p226.1",
            "order": 1,
            "type": "figure",
            "bbox": {
                "l": 55.6688,
                "t": 807.84,
                "r": 162.2073,
                "b": 785.28
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image"
            }
        },
        {
            "id": "p226.2",
            "order": 2,
            "type": "heading",
            "bbox": {
                "l": 55.6688,
                "t": 743.52,
                "r": 192.4412,
                "b": 724.8
            },
            "text": "INF 4: Drainage",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p226.3",
            "order": 3,
            "type": "list",
            "bbox": {
                "l": 53.7492,
                "t": 707.28,
                "r": 519.9752,
                "b": 474.96
            },
            "text": "",
            "attrs": {
                "item_count": 7
            },
            "children": [
                {
                    "id": "p226.3.1",
                    "order": 4,
                    "type": "list_item",
                    "bbox": {
                        "l": 53.9891,
                        "t": 707.28,
                        "r": 374.8044,
                        "b": 693.12
                    },
                    "text": "Development proposals are expected to incorporate:",
                    "marker": "1."
                },
                {
                    "id": "p226.3.2",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 109.8978,
                        "t": 680.4,
                        "r": 449.1895,
                        "b": 666.72
                    },
                    "text": "an integrated approach to the management of flood risk;",
                    "marker": "a."
                },
                {
                    "id": "p226.3.3",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.3778,
                        "t": 653.52,
                        "r": 468.8655,
                        "b": 640.08
                    },
                    "text": "a strategy for surface water, groundwater and foul drainage;",
                    "marker": "b."
                },
                {
                    "id": "p226.3.4",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.3778,
                        "t": 626.88,
                        "r": 507.7377,
                        "b": 598.8
                    },
                    "text": "management and maintenance plans incorporating any on-site and adjacent watercourses where riparian rights exist;",
                    "marker": "c."
                },
                {
                    "id": "p226.3.5",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.3778,
                        "t": 586.32,
                        "r": 492.1408,
                        "b": 557.28
                    },
                    "text": "flood resilient design that assesses and responds to the existing hydrological characteristics of a site; and",
                    "marker": "d."
                },
                {
                    "id": "p226.3.6",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.3778,
                        "t": 544.8,
                        "r": 506.7778,
                        "b": 516
                    },
                    "text": "-surface water drainage (SuDS) strategies for both minor and major schemes regardless of flood risk designation.",
                    "marker": "e."
                },
                {
                    "id": "p226.3.7",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 53.7492,
                        "t": 503.52,
                        "r": 519.9752,
                        "b": 474.96
                    },
                    "text": "Drainage strategies for development must strictly adhere to the approach of the drainage hierarchy:",
                    "marker": "2."
                }
            ]
        },
        {
            "id": "p226.4",
            "order": 11,
            "type": "text",
            "bbox": {
                "l": 109.8978,
                "t": 462.48,
                "r": 499.0994,
                "b": 433.2
            },
            "text": "Priority 1: Collect for non-potable use – rainwater harvesting (e.g. toilet flushing, irrigation)."
        },
        {
            "id": "p226.5",
            "order": 12,
            "type": "heading",
            "bbox": {
                "l": 111.0976,
                "t": 420.96,
                "r": 268.026,
                "b": 406.8
            },
            "text": "Priority 2: Control at source:",
            "level": 3
        },
        {
            "id": "p226.6",
            "order": 13,
            "type": "list",
            "bbox": {
                "l": 153.809,
                "t": 393.6,
                "r": 514.4563,
                "b": 212.16
            },
            "text": "",
            "attrs": {
                "item_count": 4
            },
            "children": [
                {
                    "id": "p226.6.1",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 160.0477,
                        "t": 393.6,
                        "r": 496.9398,
                        "b": 365.76
                    },
                    "text": "infiltration, green roofs, run-off to grass or verge, water butts, and permeable layers.",
                    "marker": "i."
                },
                {
                    "id": "p226.6.2",
                    "order": 15,
                    "type": "list_item",
                    "bbox": {
                        "l": 156.9284,
                        "t": 352.8,
                        "r": 500.2992,
                        "b": 310.08
                    },
                    "text": "on site SuDS treatment with other sustainable drainage system techniques – collection for infiltration and detention.",
                    "marker": "ii."
                },
                {
                    "id": "p226.6.3",
                    "order": 16,
                    "type": "list_item",
                    "bbox": {
                        "l": 154.2889,
                        "t": 297.12,
                        "r": 493.1006,
                        "b": 268.08
                    },
                    "text": "Local SuDS treatment with other sustainable drainage system techniques – collection away from site.",
                    "marker": "iii."
                },
                {
                    "id": "p226.6.4",
                    "order": 17,
                    "type": "list_item",
                    "bbox": {
                        "l": 153.809,
                        "t": 255.84,
                        "r": 514.4563,
                        "b": 212.16
                    },
                    "text": "Regional SuDS treatment with other sustainable drainage system techniques – collection in wetlands and balancing ponds.",
                    "marker": "iv."
                }
            ]
        },
        {
            "id": "p226.7",
            "order": 18,
            "type": "text",
            "bbox": {
                "l": 110.6177,
                "t": 199.92,
                "r": 513.7364,
                "b": 170.64
            },
            "text": "Priority 3: Discharge to watercourses – including canals, streams, ditches or existing swales."
        },
        {
            "id": "p226.8",
            "order": 19,
            "type": "text",
            "bbox": {
                "l": 111.0976,
                "t": 158.64,
                "r": 361.1272,
                "b": 144.48
            },
            "text": "Priority 4: Discharge to surface water sewers."
        },
        {
            "id": "p226.9",
            "order": 20,
            "type": "text",
            "bbox": {
                "l": 111.5775,
                "t": 131.52,
                "r": 344.0906,
                "b": 118.56
            },
            "text": "Priority 5: Discharge to combined sewers."
        },
        {
            "id": "p226.10",
            "order": 21,
            "type": "text",
            "bbox": {
                "l": 53.7492,
                "t": 105.36,
                "r": 519.2553,
                "b": 76.32
            },
            "text": "3. Solutions at lower levels of the hierarchy must only be considered when higher level solutions are demonstrably not possible or suitable. Where more than one"
        },
        {
            "id": "p226.11",
            "order": 22,
            "type": "footer",
            "bbox": {
                "l": 54.9489,
                "t": 48,
                "r": 77.7443,
                "b": 35.76
            },
            "text": "224",
            "attrs": {
                "block_label": "number"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}