{
    "document_id": 15922,
    "page": 103,
    "width_pt": 595.32,
    "height_pt": 841.92,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 16036,
    "item_count": 19,
    "counts_by_type": {
        "footer": 2,
        "footnote": 1,
        "header": 1,
        "heading": 1,
        "link": 2,
        "list": 1,
        "list_item": 10,
        "text": 1
    },
    "build_ms": 2,
    "items": [
        {
            "id": "p103.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 190.5216,
                "t": 805.2,
                "r": 523.5745,
                "b": 792
            },
            "text": "Stockport Local Plan to 2042: Publication version (regulation 19)",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p103.2",
            "order": 2,
            "type": "list_item",
            "bbox": {
                "l": 110.6177,
                "t": 764.4399999999999,
                "r": 513.4965,
                "b": 735.6
            },
            "text": "Government net zero target by 2050 / 78% reduction over 1990 levels by 2035[p103.2.1].",
            "children": [
                {
                    "id": "p103.2.1",
                    "order": 3,
                    "type": "text",
                    "bbox": {
                        "l": 110.6177,
                        "t": 764.4399999999999,
                        "r": 513.4965,
                        "b": 735.6
                    },
                    "text": "⁷⁶",
                    "attrs": {
                        "inline": true,
                        "text_offset": 75,
                        "text_span": 10,
                        "bbox_estimated": true
                    }
                }
            ]
        },
        {
            "id": "p103.3",
            "order": 4,
            "type": "link",
            "bbox": {
                "l": 182.2,
                "t": 749.92,
                "r": 195.6,
                "b": 724.12
            },
            "text": "76 .",
            "attrs": {
                "target_page": 103,
                "action_type": "/GoTo"
            }
        },
        {
            "id": "p103.4",
            "order": 5,
            "type": "heading",
            "bbox": {
                "l": 54.2291,
                "t": 687.6,
                "r": 464.5464,
                "b": 668.88
            },
            "text": "CR 2: Energy efficiency, resources and carbon",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p103.5",
            "order": 6,
            "type": "list",
            "bbox": {
                "l": 52.3095,
                "t": 651.36,
                "r": 522.3747,
                "b": 144.24
            },
            "text": "",
            "attrs": {
                "item_count": 9
            },
            "children": [
                {
                    "id": "p103.5.1",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 54.2291,
                        "t": 651.36,
                        "r": 515.4161,
                        "b": 547.92
                    },
                    "text": "The design and construction of development should minimise energy consumption and carbon emissions in new buildings, infrastructure and public realm projects, and deliver appropriate energy improvements to existing buildings. This should be demonstrated by the provision of an ‘energy and carbon statement’ (to include a low carbon heat appraisal where relevant) with the level of detail proportionate to the scale of development proposed. All relevant developments must follow the energy hierarchy:",
                    "marker": "1."
                },
                {
                    "id": "p103.5.2",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 111.3376,
                        "t": 536.64,
                        "r": 268.2659,
                        "b": 522.24
                    },
                    "text": "Minimise energy demand;",
                    "marker": "1)"
                },
                {
                    "id": "p103.5.3",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.8577,
                        "t": 509.52,
                        "r": 278.8238,
                        "b": 495.84
                    },
                    "text": "Maximise energy efficiency;",
                    "marker": "2)"
                },
                {
                    "id": "p103.5.4",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.6177,
                        "t": 483.36,
                        "r": 266.1064,
                        "b": 468.96
                    },
                    "text": "Utilise renewable energy;",
                    "marker": "3)"
                },
                {
                    "id": "p103.5.5",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.6177,
                        "t": 456.96,
                        "r": 318.6558,
                        "b": 442.32
                    },
                    "text": "Utilise low carbon energy; and then",
                    "marker": "4)"
                },
                {
                    "id": "p103.5.6",
                    "order": 12,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.8577,
                        "t": 429.6,
                        "r": 283.3829,
                        "b": 415.68
                    },
                    "text": "Utilise other energy sources.",
                    "marker": "5)"
                },
                {
                    "id": "p103.5.7",
                    "order": 13,
                    "type": "list_item",
                    "bbox": {
                        "l": 52.3095,
                        "t": 403.44,
                        "r": 519.9752,
                        "b": 330
                    },
                    "text": "There is an expectation that new build development will, unless it can be demonstrated that it is not technically feasible or financially viable, be net zero carbon for operational energy. New build development providing at least 1 dwelling or 100 square metres of non-residential floorspace (measured on gross internal area - GIA) must:",
                    "marker": "2."
                },
                {
                    "id": "p103.5.8",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 110.1378,
                        "t": 317.76,
                        "r": 516.136,
                        "b": 259.44
                    },
                    "text": "Use a nationally recognised predictive energy model to demonstrate space heating demand and energy use intensity, such as Passive House Planning Package (PHPP) for residential and PHPP or TM54 for non-residential (or accepted equivalent).",
                    "marker": "a."
                },
                {
                    "id": "p103.5.9",
                    "order": 15,
                    "type": "list_item",
                    "bbox": {
                        "l": 109.8978,
                        "t": 247.68,
                        "r": 522.3747,
                        "b": 144.24
                    },
                    "text": "Maximise opportunities for renewable energy generation from solar technology through site layout, building orientation and design, and must provide solar photovoltaic panels on the roof space equivalent of at least 40% of the building footprint, unless there would be unacceptable impacts on amenity, safety (including glint and glare) or result in harm to the significance of heritage assets which is not clearly and convincingly justified and outweighed by public benefit.",
                    "marker": "b."
                }
            ]
        },
        {
            "id": "p103.6",
            "order": 16,
            "type": "footnote",
            "bbox": {
                "l": 53.7492,
                "t": 84.72,
                "r": 282.903,
                "b": 70.08
            },
            "text": "76 See www.legislation.gov.uk/uksi/2021/750/made",
            "attrs": {
                "block_label": "footnote"
            },
            "children": [
                {
                    "id": "p103.6.1",
                    "order": 17,
                    "type": "link",
                    "bbox": {
                        "l": 85.03,
                        "t": 83.519,
                        "r": 283.53,
                        "b": 72.02
                    },
                    "text": "www.legislation.gov.uk/uksi/2021/750/made",
                    "attrs": {
                        "uri": "http://www.legislation.gov.uk/uksi/2021/750/made",
                        "action_type": "/URI"
                    }
                }
            ]
        },
        {
            "id": "p103.7",
            "order": 18,
            "type": "footer",
            "bbox": {
                "l": 54.2291,
                "t": 53.76,
                "r": 381.763,
                "b": 26.64
            },
            "text": "Ambitious Stockport, creating opportunities for everyone",
            "attrs": {
                "block_label": "footer"
            }
        },
        {
            "id": "p103.8",
            "order": 19,
            "type": "footer",
            "bbox": {
                "l": 502.4587,
                "t": 48.48,
                "r": 523.3345,
                "b": 35.28
            },
            "text": "101",
            "attrs": {
                "block_label": "number"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}