    "document_id": 15196,
    "page": 113,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 15308,
    "item_count": 21,
    "counts_by_type": {
        "figure": 1,
        "footer": 1,
        "heading": 5,
        "list": 1,
        "list_item": 4,
        "text": 8,
        "title": 1
    },
    "build_ms": 2,
    "items": [
        {
            "id": "p113.1",
            "order": 1,
            "type": "figure",
            "bbox": {
                "l": 29.76,
                "t": 775.44,
                "r": 163.68,
                "b": 646.8
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image"
            }
        },
        {
            "id": "p113.2",
            "order": 2,
            "type": "title",
            "bbox": {
                "l": 196.8,
                "t": 733.2,
                "r": 516,
                "b": 679.44
            },
            "text": "KENTUCKY STATE UNIVERSITY\nBoard of Regents",
            "attrs": {
                "block_label": "doc_title"
            },
            "level": 2
        },
        {
            "id": "p113.3",
            "order": 3,
            "type": "heading",
            "bbox": {
                "l": 87.36,
                "t": 630,
                "r": 330,
                "b": 616.56
            },
            "text": "• Emergency Generator Replacement",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p113.4",
            "order": 4,
            "type": "text",
            "bbox": {
                "l": 106.56,
                "t": 615.12,
                "r": 260.16,
                "b": 602.16
            },
            "text": "State Account Number C916"
        },
        {
            "id": "p113.5",
            "order": 5,
            "type": "text",
            "bbox": {
                "l": 105.12,
                "t": 600.96,
                "r": 539.76,
                "b": 556.08
            },
            "text": "Scope of Work – Replace and reposition emergency generator at the chilled water plant. Contract of $296,000 awarded to Kentuckyana Electrical Services; the generator was installed August 3 and all is fully operational."
        },
        {
            "id": "p113.6",
            "order": 6,
            "type": "heading",
            "bbox": {
                "l": 87.84,
                "t": 541.2,
                "r": 326.4,
                "b": 527.52
            },
            "text": "• Replace Exterior Stairs at Bell Gym",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p113.7",
            "order": 7,
            "type": "list",
            "bbox": {
                "l": 105.36,
                "t": 526.08,
                "r": 490.56,
                "b": 467.76
            },
            "text": "",
            "attrs": {
                "item_count": 4
            },
            "children": [
                {
                    "id": "p113.7.1",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 106.08,
                        "t": 526.08,
                        "r": 262.32,
                        "b": 513.12
                    },
                    "text": "State Account Number C96P"
                },
                {
                    "id": "p113.7.2",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.6,
                        "t": 511.44,
                        "r": 449.76,
                        "b": 498
                    },
                    "text": "Scope of Work – Replace exterior stairs at north end of building."
                },
                {
                    "id": "p113.7.3",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.6,
                        "t": 495.84,
                        "r": 490.56,
                        "b": 482.88
                    },
                    "text": "Bid documents are ready to advertise; construction estimate is $70,000."
                },
                {
                    "id": "p113.7.4",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.36,
                        "t": 481.68,
                        "r": 424.32,
                        "b": 467.76
                    },
                    "text": "Construction on hold pending full funding for construction."
                }
            ]
        },
        {
            "id": "p113.8",
            "order": 12,
            "type": "heading",
            "bbox": {
                "l": 87.6,
                "t": 451.92,
                "r": 265.68,
                "b": 438.48
            },
            "text": "• Construct Softball Field –",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p113.9",
            "order": 13,
            "type": "text",
            "bbox": {
                "l": 105.6,
                "t": 436.8,
                "r": 263.28,
                "b": 423.6
            },
            "text": "State Account Number C96Q"
        },
        {
            "id": "p113.10",
            "order": 14,
            "type": "text",
            "bbox": {
                "l": 104.4,
                "t": 422.4,
                "r": 537.84,
                "b": 393.12
            },
            "text": "Scope of Work – Design on campus softball field – awaiting revised cost estimate before deciding to proceed. Preliminary budget of $48,000."
        },
        {
            "id": "p113.11",
            "order": 15,
            "type": "heading",
            "bbox": {
                "l": 88.08,
                "t": 376.8,
                "r": 344.16,
                "b": 363.6
            },
            "text": "• Mold Remediation in Exum Basement",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p113.12",
            "order": 16,
            "type": "text",
            "bbox": {
                "l": 106.32,
                "t": 361.92,
                "r": 261.6,
                "b": 348.72
            },
            "text": "State Account Number C97F"
        },
        {
            "id": "p113.13",
            "order": 17,
            "type": "text",
            "bbox": {
                "l": 104.88,
                "t": 347.28,
                "r": 532.08,
                "b": 318.48
            },
            "text": "Scope of Work – Mold remediation; project budget $25,000 – portions of finish work is still to be completed."
        },
        {
            "id": "p113.14",
            "order": 18,
            "type": "heading",
            "bbox": {
                "l": 88.08,
                "t": 302.4,
                "r": 329.52,
                "b": 289.2
            },
            "text": "• Install Access Control at Hume Hall",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p113.15",
            "order": 19,
            "type": "text",
            "bbox": {
                "l": 105.6,
                "t": 287.28,
                "r": 261.36,
                "b": 274.32
            },
            "text": "State Account Number C97Y"
        },
        {
            "id": "p113.16",
            "order": 20,
            "type": "text",
            "bbox": {
                "l": 105.36,
                "t": 272.88,
                "r": 477.36,
                "b": 244.32
            },
            "text": "Scope of Work – Wiring to install access control system at Hume Hall Preliminary budget is $10,000."
        },
        {
            "id": "p113.17",
            "order": 21,
            "type": "footer",
            "bbox": {
                "l": 258.96,
                "t": 47.04,
                "r": 352.56,
                "b": 37.2
            },
            "text": "Page 113 of 126",